During recovery, the thermostat increases the
control temperature gradually and turns the
equipment on and off several times BEFORE
reaching your comfort time to save energy by
avoiding overshooting the comfort temperature.
You can see the current control temperature
anytime during recovery by pressing the CUR-
RENT SETTING key.
This smart control learns from experience. Each
day it checks how closely it hit the target and
adjusts the recovery start time accordingly. It
normally takes FOUR TO EIGHT DAYS AFTER
INSTALLATION for the thermostat to adjust to
the weather, your lifestyle, home construction
and heating/cooling system.
With conventional recovery, the programmed
time will mark the start of the time your furnace
or air conditioner comes on to start recovery;
therefore, you should program the start time to
be earlier than the desired comfort time. The
best starting time will vary as the seasons
change, but 30 minutes is a good head start
time to use.
NOTE: If you adjust screw 3A for conventional
recovery, a
right corner of the thermostat display as a
reminder that you are
no longer using the
Adaptive Intelligent
Recovery™ feature.
8
indicator will appear in the lower
TUE
DAYTIME
INDICATES
THERMOSTAT IS SET FOR
CONVENTIONAL RECOVERY
69-0733B—1