Match Lighting Instructions; Cleaning And Service - Monessen Hearth VFCS30DNV Installation & Operating Manual

Unvented gas cast iron stove single door models
Table of Contents

Advertisement

Unvented Cast Iron Gas Stoves
1. Open stove door. Remove any items necessary for
easy access to the pilot (for example: logs, screens,
etc.).
2. Follow appropriate lighting instructions found previously.
Instead of pushing and releasing the piezo button, light
a match and hold the flame to the end of the pilot and
ignite the pilot.
Cleaning & Service
!
Turn off heater and allow to cool before cleaning.
Disconnect electrical power before cleaning or
servicing.
Annual inspection and cleaning by your dealer or
qualified service technician is recommended to prevent
malfunction and/or sooting.
Remove logs, handling carefully by holding gently at each
end. Gloves are recommended to prevent skin irritation from
ceramic fibers. If skin becomes irritated, wash gently with
soap and water. Refer to manual for correct log placement.
Periodic Cleaning - See parts diagram for location of
items discussed below.
• Do not use cleaning fluid to clean logs or any part of
heater.
• Brush logs with soft bristle brush or vacuum with brush
attachment.
• Vacuum loose particles and dust from the front and rear
burners, control and piezo covers and grate weldment.
• Inspect and clean burner air intake holes. Remove lint or
particles with vacuum, brush, or pipe cleaners. Failure
to keep air intake holes clean will result in sooting and
poor combustion.
• External case should be dusted and wiped with a moist
cloth.
19

MATCH LIGHTING INSTRUCTIONS

WARNING
Monessen • Concorde VF Installation Manual_R11 • 02/17
3. After control knob has been released and pilot stays lit,
reinstall any items that were removed for pilot access.
4. Call a qualified service technician for repair or
replacement of the piezo ignitor.
Annual Cleaning / Inspection - Refer to parts diagram for
location of items discussed below.
• Inspect and clean burner air intake holes. Remove lint
or particles with vacuum, brush or pipe cleaners. Failure
to keep air intake holes clean will result in sooting and
poor combustion.
• Inspect and clean all burner ports.
• Inspect ODS pilot for operation and accumulation of lint
at air intake holes.
• Verify flame pattern and log placement for proper
operation.
• Verify smooth and responsive ignition of main burner
and rear burner.
3-90-58D6002