Nilfisk-Advance ATTIX 33-01 IC Service Manual page 26

Attix 33/44 & vhs 40/42 l + m + h series

Advertisement

26
When?
Flow sensor calibration should be carried out, if the PBCA or flow sensor has been changed
during service. Also it is recommended to do a flow sensor calibration, if the motor unit has
been replaced.
1
2
Flow sensor calibration
26
Switch off the machine, disconnect the
mains plug and take off handle and top cover
as described in previous Section E.0.
Connect the calibration switch tool (P/N:
107416579) to connector (A) on the PCBA
(fig.1).
Position the hose diameter selector to posi-
tion "Ø32" (fig.2).
Insert the air restrictor with manometer (P/N:
62480 + P/N 40434) into the container inlet
(fig.3).
3
foto
E.8