Unit Fails to Power On
fully inserted into the power socket on the unit.
Excess Air / Fail
—The Mini ID is equipped with a unique filter located between the coupler and hose. This is a
disposable filter designed to trap oil and sealant to prevent damage to the unit. Remove and inspect the filter
for oil etc. and replace if necessary. Remove any oil in the coupler with compressed air and a dry cloth.
Replacement Filter P/N 6-01-6001-23-1
The Mini ID is equipped with internal fault codes for assistance with troubleshooting. When the "FAULT" light
is illuminated, the code is determined by counting the number of flashes.
Code 3 = Calibration Error
Code 4 = Temperature Error
Code 5 = Calibration Compensation Error
Should one of these codes appear, take the following action prior to contacting you
Service Representative.
Sp. Z o.o.
1. Disconnect the power from the instrument and verify the power source is between 12 and 15 VDC.
2. Place the unit in a climate controlled area between 15°C and 27°C.
3. Fully Squeeze the Calibration Bulb 10 times.
4. Allow the unit to remain in the climate controlled room for 30 minutes.
5. Reconnect the unit and re-test.
If these steps fail to restore the unit to good working order, contact:
- Check the voltage and polarity of the power source. Ensure that the power plug is
Magneti Marelli Aftermarket Spółka z.o.o.
Plac Pod Lipami 5, 40-476 Katowice
Tel.: + 48 (032) 6036107, Faks: + 48 (032) 603-61-08
e-mail:
checkstar@magnetimarelli.com
www.magnetimarelli-checkstar.pl
Magneti Marelli Aftermarket

Advertisement

Table of Contents
loading

Table of Contents