OPerating inStructiOnS FOr DSi MODelS
Warning! iF YOu DO nOt FOllOW tHeSe inStructiOnS eXactlY, a Fire Or eXPlOSiOn
MaY reSult cauSing PrOPertY DaMage, PerSOnal injurY Or lOSS OF liFe.
Warning! beFOre OPerating Water Heater, be Sure tanK iS FilleD WitH Water.
A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not
try to light the burner by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
Do not try to light any appliance.
Do not touch any electric switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions
If you cannot reach your gas supplier, call the fire department.
C. This is an automatic gas valve, no adjustments are necessary. Do not
attempt to repair the gas valve. This may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately
call a qualified service technician to inspec the application and to
replace any part of the control system and any gas control which has
been under water.
E. Before operating water heater, check the location of th event to
make sure it will not be blocked by the opening of any door on the
trailer. If it can be blocked, do not operate the water heater with the
door open.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information provided.
2. Turn off all electric power to the appliance.
3. Turn "OFF" gas supply.
4. Wait five(5) minutes for gas to clear the area. If you smell gas
then STOP! Follow instructions in items B above, under SAFETY
INFORMATION. If you do not smell gas, go to the next step.
5. Turn "ON" gas supply.
6. Turn on electrical power to the appliance.
7. Turn switch to "ON" position. If the burner does not light, the system will automatically attempt two more tries for
ingnition before lock-out. NOTE: Each ignition cycle will have a 15 second purge before spark cycle if system is a three
try system.
8. If LOCKOUT occurs before main burner lights, turn switch to "OFF," wait five(5) seconds and turn switch to "ON"
poistion. This will restart the ignition cycle. The first start-up of the heater may require several ignition cycles before all
air is purged from the gas lines.
If the burner will not come on, the following items should be checked.
1. Switch turned "OFF."
2. Gas supply to heater is empty or turned off.
3. Reset button on ECO is tripped.
See "SaFetY WarningS."
SAFETY INFORMATION
WHAT TO DO IF YOU SMELL GAS
14
WATER HEATER
ON
RESET