Page 1
PELLET S MODUL E P 6 / P 7 LC P 70 LC P 75 A LC P 75 B(-Z) LC P 80 (-Z) U S ER M ANUAL WITH I NSTAL L ATION I N S TRU CT I O NS Edition July 2010 page 1...
Switching on the appliance 33. Menu diagram ............26 Switching off the appliance 34. After-sales service /Ordering spare parts ....27 Setting the heating output 35. The LOHBERGER WARRANTY ........27 18. Main menu ..............13 SHORT INSTRUCTION ............28 17. Menu Settings ............13 Keylock...
Page 3
With this solid fuel-fired stove you have selected a high-quality product made by LOHBERGER. Apart from the beautiful and timeless design we attach great importance to a fully developed combustion technique, high-quality materials as well as perfect workmanship. Correct handling and proper care are a prereq- uisite for high reliability and a long service life.
Page 4
In case of queries please do not hesi- tate to contact the technical customer service of LOHBERGER. Caution! Possible risks of burns!
2. Technical data 2. Technical data Cover Protective grating Auger Control panel Pellet storage container Flame bruck Sidewall built-in cupboard Door contact shifter Extraction shaft Base panel lateral Drive shaft - rotary feeder Burner brick Base panel front Driving chain-conveying unit Grate unit Front panel built-in cupboard Auger motor...
3. Types of operation 3. Types of operation The pellet stove can be operated either with wood pellets or billet wood. Operation with pellets The operation with pellets is predominantly suitable for heating the room where the appliance is installed. In this case the appliance is controlled by the use of preset control variables.
5. Fuels 5. Fuels Suitable fuels WOOD PELLETS It is imperative that only wood pellets conforming to the Austrian standards ÖNORM M7135 or DIN Plus are used. Diameter 6 mm, length max. 30 mm. Storage of wood pellets Pellets are supplied with a maximum water content of 10 %. Wood pellets must not be exposed to humidity during transport, make sure that they are stored in fig.
7. Requirements for the room where the appliance is situated 7. Requirements for the room where the appliance is situated Floor - load capacity Room and ambient temperatures /humidity Prior to installing the appliance, make sure that the substruc- The appliance is suitable for rooms with normal humidity and ture of the floor is suitable to bear the weight of the appliance.
9. Heating connection 9. Heating connection Flue pipe connection left side: Output requirements for heating water 53,5 Heat requirement during operation must exceed 1,6 kW. If the heat output falls Heating flow 1“ below this value, the built-in safety devices will be activated and /or the appli- ance will be shut down.
When attached to combustible materials or installed in a built-in kitchen or attachment to an electric stove or any other appliance, a fire protection The Lohberger fire protection units VBS have only been tested in connection with The Lohberger fire protection units VBS have only been tested in connection with the Lohberger –...
13. Scope of supply 13. Scope of supply Base (bottom) Sidewall preassembled Front panel preassembled Base cover front Mounting accessories enamel covering Sheet metal screw 4,2 x 10 mm 8 pcs. fig. 14 14. Installing the panels 14. Installing the panels Base (bottom) Place the base (A) in front of the appliance and push it from the front under the pellets module.
To raise the heating output, press in the top level of the menu. Adjustment range heating output: 3 – 10 for air heaters (P6) 5 – 10 for central heating appliances (P7, type-designation –Z) page 12...
Key lock The key lock prevents an accidental adjustment of the appliance settings (e.g. The key lock prevents an accidental adjustment of the appliance settings (e.g. when cleaning the control panel, caused by children, …) and can be switched on when cleaning the control panel, caused by children, …) and can be switched on or off if required or off if required...
Adjust by pressing the buttons Press button once, the set value is stored and the display Year flashes Press button once, the set value is stored Press 3 times to return to the top level of the menu. Automatic mode The automatic operation determines whether the appliance is operated manually The automatic operation determines whether the appliance is operated manually (standard setting OFF) or whether the internal clock is used for switching the ap-...
Key lock (function) -- Settings -- automatic mode To use the key lock in the top level of the menu, the key lock function must be To use the key lock in the top level of the menu, the key lock function must be Heating period activated.
Summer/Winter (only for appliances with central heating insert) -- Settings -- Service code To reduce heat output in summer, the appliance can be changed from winter to To reduce heat output in summer, the appliance can be changed from winter to reset summer mode.
Actuators -- informations -- Sensors Select the menu Actuators in the menu Information by pressing the button >actuators < and press the once (figure 48). System/SWversion |% Paging through the menu items is possible by means of pressing the button fig.
| | | Adjustment range heating output: fig. 58 3 - 10 for air heaters (P6) 5 - 10 for central heating appliances (P7, type designation -Z) If the heating output is not sufficient although it has been set at the highest level, the temperature can be increased by loading firewood.
22. Heating operation with firewood 22. Heating operation with firewood Ignition of firewood manually operated • Set the regulator for primary air (bottom) to level 3 and set the regulator • Set the regulator for primary air (bottom) to level 3 and set the regulator for secondary air to level 6.
We offer you the possibility to conclude a yearly maintenance contract. If you wish to take advantage of this service, please do not hesitate to contact the customer to take advantage of this service, please do not hesitate to contact the customer service department of LOHBERGER service department of LOHBERGER ®...
26. Maintenance / Cleaning 26. Maintenance / Cleaning Before starting with the cleaning and /or maintenance, the appliance must be shut Before starting with the cleaning and /or maintenance, the appliance must be shut down and disconnected from the mains (Emergency - OFF). Allow the appliance to down and disconnected from the mains (Emergency - OFF).
Cleaning ash pan (figure 70) CAUTION! Ash pan can be hot!! CAUTION! Ash pan can be hot!! • Remove the base cover front (H1). • Pull out the ash pan (in a forward direction). • Empty ash pan and clean ash drawer space. Vacuum-cleaning ash drawer space Allow the appliance to cool down completely and use vacuumcleaner only in combination with an »...
Page 23
Power failure Correct defect, allow boiler to cool down, reset STB manually. Failure heating circuit pump Overheating, max. permissible boiler temperature (95 °C) was Radiator adjusted to low opera- Open customer, the heating installer should have a look at exceeded, safety temperature StB activateD tion (possibly thermal valve) the heat customer if it occurs frequently...
3 30. Type test 30. Type test The Lohberger Pellet module was successfully tested by the Technical University of Vienna according to the current European Standards. Report testing institute no . PL-0418-P-E Die Emissionen gemäß Art. 15a B-VG über Schutzmaßnahmen und über die Einsparung von Energie werden eingehalten.
Boiler pump blue brown Oven/Exhaust gas sensor white black Plug-in sensor Auger motor Earthing white white Contact change-over damper Bridge (P6) Boiler sensor white (P7) Earthing (Resetting safety temperature limiter) black Serial input /output Capacitor (RS 232, Maintenance/Update) Capacitor Induced draught...
Duration of the Warranty Repairs In principle, LOHBERGER grants a 3-year full warranty on verifiable We will carefully check your appliance and establish whether material or factory defects on every appliance. Warranty expires in the warranty claim is justified. If yes, we will decide in which any case after five years following the manufacture of the appliance.