The standard unit requires 1 20/2 40 VAC control power to
operate. See Figure 2.1A (page 6). The unit mounted with a
three-phase Power Module draws its power from the line it is
monitoring.

1.3 Use of Manual-

This manual is designed for use during
installation and troubleshooting and, if necessary, unit re­
placement. It also has information of specific importance for
the user's application engineer who is planning the overall
system and who is determining the setpoint values for a
specific IQ Data application.
The manual is broad enough in scope to form the basis of new
employee familiarization, refresher training sessions, and on­
going maintenance.
Microprocessor-based control
Two models
Simplified programming
Standard cutout
Communication to an IBM PC (or clone) personal com-
puter. This computer acts as the master and can also
be used as the interface to other microprocessor-based
devices.
Communications via RS232C to other microprocessor-
based products or phone modems.
IQ DATA FEATURES AND BENEFITS
Feature
C OMMUNICAT ION ARRANGEMEN TS
Feature
It is strongly advised that the application engineer carefully
read Sections 2 thru 5 before producing the application's wiring
plan drawings and filling out the Setpoint Record Sheet.
Installation teams should carefully read all of Section 4
starting final installation. Maintenance personnel should be
familiar with Section 7 before attempting to service the IQ Data.

1.4 Level of Repair

sumption that only unit-level troubleshooting will be performed.
If the cause of malfunction is traced to an IQ Data, the unit
should be replaced with a spare. The malfunctioning unit
should then be returned to Westing house for factory repairs.
Table 1.A
Reliable service without the need for numerous exter-
nal measuring instruments.
Ease of purchasing, stocking
In many cases eliminates external transformers
Simplified wiring
No special languages to learn
One hole to cut
Interchangeability with IQ Data Plus II, IQ Generator
Table 1.B
A Local Area Network, Westinghouse INCOM, is formed
by 2 or more IQ Datas connecting to a personal computer
via a shared twisted pair of wires. The personal computer
acts as a master. In this arrangement the PONI Commu-
nication Module is mounted on each IQ Data. A CONI
Communication Card is used in an expansion slot of the
personal computer. A standardized software package is
provided with the CONI Card for data collection and
storage.
Using INCOM, 2 or more IQ Datas (or other IQ products),
each with a PONI Communication Module, can be con-
nected to the two wire network to transmit data to a sin-
gle Translator Module. This module converts INCOM
formatted messages to RS232C for use with other
RS232C compatible devices. No software is provided in
this case.