Door parameters
Single-panel sliding door
– Clear passage width LW
– Door panel weight, max.
Double-panel sliding door
– Clear passage width LW
– Door panel weight, max.
Clear passage height*
*Other dimensions on request.
Technical data of operator
Height
Installation depth
Opening and closing force, max. 150 N
Opening speed
(incremental setting)
Closing speed
(incremental setting)
Hold-open time
Supply voltage, frequency
Power consumption
Class of protection
Admissible temperature
Admissible humidity (relative)
Compliant with EU
Low Voltage Directive and EMC Directive
Manufactured to ISO 9001
Environmental product declaration in
accordance with ISO 14025
Programme holder: Institute Construction
and Environment e.V.
Declaration number: EPD-DOR-2013511-E
ES 200
Basic module (BM)
Modular design
700 – 3000 mm
Microprocessor-controlled function programs
1 x 200 kg
800 – 3000 mm
2 x 160 kg
2100 – 3200 mm
Connections for
Adjustment of all basic parameters
100 and 150 mm
via integrated display and pushbuttons
180 mm
24 V output for external accessory
3
Read-out error memory with error codes
DCW
bus interface (Protokoll DORMA Connect and Work)
10 – 70 cm/s
®
Rechargeable battery pack for emergency operation
10 – 50 cm/s
0 – 180 s
Function module (FM) – optional extra
230 V, 50/60 Hz
Pharmacy Function
250 W
Door status contact (three)
IP 20
Main and secondary closing edge protection
- 20 – + 60 °C
Panic Closing Function
max. 93 %
(non condensing)
Bell contact
3
Airlock control
Synchronous operation
3
DIN 18650 and EN 16005 function module – optional
3
The DIN 18650 and EN 16005 function module
enables the tested monitoring of the secondary closing
edges in order to comply with the German standard
DIN 18650 and EN 16005.
Additional equipment
Electro-mechanical locking device (bistable)
Manual lock release for electro-mechanical locking device
Light barriers
Rechargeable battery pack
(emergency opening, emergency closing)
Module for coupling to EIB or
LON building management systems
Infrared detector
3 standard
ES 200
– Off
– Automatic
– Permanent Open
– Partial Open
– Exit Only
– Night-/Bank Function
– electro-mechanical locking device
– light barriers
§ optional