Summary of Contents for Dorma ES 90

  • Page 1 DORMA ES 90/100...
  • Page 2 DORMA , .. UK training department1 2/25/20044:14...
  • Page 3 t-.A.,;f DORM" • • UKT~aining Dcpartll1e'nt'<. ,-- <-" UK training departmentl 2/25/20044:14...
  • Page 4 DORMA UK training department1 2/25/20044:14...
  • Page 5 DORMP UK training department1 2/25/20044:14...
  • Page 6 _~I ~\ DORMA • _ES_90/_100 DORMA Commissioning Adjustment Functional testing Work on electrical equipment must only be Ir\. When using the ES concealed rod multipoint lock, performed trained and qualified electricians. perform the procedures specified under step 8 overleaf: Concealed rod multipoint lock.
  • Page 7 E_S90_/lOO__ DORMA Activators 5. Further information Test all connected activators in the various program The door system performs a self-test every 4 hours or switch settings. Perform settings and adjustments at appropriate times after the system has been the activators...
  • Page 8 CORMA • ES 901100 DORMA 7. Force limitation E5 901100 control units with motor type GR 63x@ Opening speed: 7.1 Adjusting the static force limits Creep speed CLOSE, as per ZH 1/494 and pr EN 12650 Creep speed distance CLOSE,...
  • Page 9 ------------- ES90/100 DORMA Check the wiring and perform a directional test. In Buzzer, selectable via DIP switch so doing, monitor the signals at the control unit of Ix signal means unlocking successfully the concealed rod multipoint lock. completed. After a locking signal has been emitted, 3x signals means locking successfully completed.
  • Page 10 The Rev. 8 control differs from the older control unit in respect of the following points: It has a larger EPROM. The EPROMs can not be used in the pre-Rev. 8 control units. ES 90/100 control, Rev. 8, with concealed multipoint lock. The concealed rod multipoint...
  • Page 11: Troubleshooting

    DORMA • DORMA -_-_-E_S_9~O/~lO~O Troubleshooting See also Commissioning Adjustment Functional testing. In the event of faults during start-up or operation, first check the following points; Mains power available? Emergency stop pushbutton unlatched? Program switch in the correct position? Light barrier transmission...
  • Page 12 DORMA • ES 901l00~ DORMA Troubleshooting for concealed rod multipoint lock Fault Possible cause Remedy Motor does not respond. Fault Operate the program switch in the sequence: "AUTOMATIC" - "OFF" - "AUTOMATIC". Manual unlocking has interrupted Check the continuity from terminal motor supply.
  • Page 13 E5901l00 nORMA Diagnostics port Service displays Operational display. basic module (GM) Once the mains power has been switched on, the power supply unit is energised. This takes about 20 seconds, after which the LED lights up. LED-display Condition Function Normal mode - Mains power available, Normal mode power supply unit energised unit not receiving mains power...