Milwaukee Mi 190 Manual
Milwaukee Mi 190 Manual

Milwaukee Mi 190 Manual

Benc meter do/temperature

Advertisement

Quick Links

THANK YOU FOR CHOOSING
Sales and Technical Service Contacts:
Milwaukee Electronics Kft.
Alsókikötő sor 11.
6726, Szeged, Hungary
Tel: +36-62-428-050
Fax: +36-62-428-051
e-mail: sales@milwaukeeinst.com
Milwaukee Instruments, Inc.
2950 Business Park Drive Rocky Mount, NC
27804 USA
Tel: +1 252 443 3630
Fax: +1 252 443 1937
e-mail: sales@milwaukeetesters.com
www.milwaukeeinst.com
MANMI190R1
10/05
www.milwaukeeinst.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mi 190 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Milwaukee Mi 190

  • Page 1 THANK YOU FOR CHOOSING Sales and Technical Service Contacts: Milwaukee Electronics Kft. Alsókikötő sor 11. 6726, Szeged, Hungary Tel: +36-62-428-050 Fax: +36-62-428-051 e-mail: sales@milwaukeeinst.com Milwaukee Instruments, Inc. 2950 Business Park Drive Rocky Mount, NC 27804 USA Tel: +1 252 443 3630 Fax: +1 252 443 1937 e-mail: sales@milwaukeetesters.com...
  • Page 2: Table Of Contents

    Instruction Manual Mi 190 DO Bench Meter www.milwaukeeinst.com FUNCTIONAL DESCRIPTION ..................2 For your Safety don’t use or store the instrument in hazardous environments. To avoid GENERAL DESCRIPTION .................... .4 damages or burns, do not perform any measurement in microwave ovens.
  • Page 3 Instruction Manual Mi 190 DO Bench Meter www.milwaukeeinst.com TROUBLESHOOTING FUNCTIONAL DESCRIPTION SYMPTOMS PROBLEM SOLUTION FRONT PANEL FRONT PANEL FRONT PANEL FRONT PANEL FRONT PANEL Reading fluctuates up and DO probe not properly Insert the probe. 1. Liquid Crystal Display (LCD) down (noise).
  • Page 5: Specifications

    Instruction Manual Mi 190 DO Bench Meter www.milwaukeeinst.com <ETX> is 03 ASCII code character (end of text) SPECIFICATIONS <answer>: <ACK> is sent for a recognized command Range 0.00 to 45.00 ppm O <CAN> is sent when the instrument is logging 0.0 to 300.0 % O...
  • Page 7: Probe Connection And Preparation

    If the temperature measurements are inaccurate, temperature recalibration should be performed. For an accurate recalibration, contact your dealer or the nearest Milwaukee Customer Service pins with the socket located on the back of the meter, pushing the plug in and tightening the threaded ring.
  • Page 8: Operational Guide

    Instruction Manual Mi 190 DO Bench Meter www.milwaukeeinst.com OPERATIONAL GUIDE A l t i t u d e , M e t e r s a b o v e S e a L e v e l º C º...
  • Page 9: Salinity And Altitude Compensation

    Instruction Manual Mi 190 DO Bench Meter www.milwaukeeinst.com The salinity affects the D.O. concentration, decreasing its value. The table below shows the Before proceeding with the calibration, make sure the probe is ready for measurements (see page 7), maximum oxygen solubility at various temperatures and salinity levels.
  • Page 10: Temperature Measurements

    Instruction Manual Mi 190 DO Bench Meter www.milwaukeeinst.com Press the arrow keys to change the displayed value. • Press RANGE to change the reading from % to ppm and vice-versa. Press the ACCEPT key to accept the value or the CAL key to escape.
  • Page 11: Calibration

    The zero calibration of the Mi 190 Mi 190 Mi 190 Mi 190 Mi 190 is very stable, therefore this procedure needs to be • Altitude Compensation performed only whenever the probe or the membrane is replaced. • Current Time (hh:mm) However, because the slope calibration is more critical, it is recommended to perform this •...
  • Page 12 Instruction Manual Mi 190 DO Bench Meter www.milwaukeeinst.com • The salinity factor • Press CAL. The “WAIT” tag will blink on the LCD until the reading is stable. • The altitude factor • When the reading is stable, “READY” & “ACCEPT” tags start blinking. Press ACCEPT to confirm the “0.0%”...
  • Page 13: Slope Calibration

    N o t e : N o t e : tags will blink. • MI 190 has automatic buffer recognition function. If the ARROW keys are pressed to select the desired calibration value, the automatic buffer recognition function is disabled.
  • Page 14: Logging

    Instruction Manual Mi 190 DO Bench Meter www.milwaukeeinst.com LOGGING If the log space is full, “FULL LOC” message will be displayed and no more data will be saved. When the LOG key is pressed while in measurement mode, a complete set of informa- Up to 50 LOG samples can be stored into memory tion is stored.