Alcatel-Lucent 7210 SAS D Service Manual page 194

Hide thumbs Also See for 7210 SAS D:
Table of Contents

Advertisement

Basic Configurations
meter 4 create
exit
meter 5 create
exit
scope template
default-fc
fc af
exit
fc l1
exit
fc h2
exit
fc h1
exit
mac-criteria dot1p-only
entry
exit
entry 2
exit
entry 3
exit
entry 4
exit
exit
In the example above, assuming the policy is attached to a SAP in a VPLS service, the
classification entries used per FC are:
FCnc = 0 + 0 + 0 + 0 = 0
FCh1 = 1 + 1 + 1 + 1 = 4
Since this FC uses unicast, broadcast, multicast and unknown-unicast meter, four entries are
needed to identify these traffic types explicitly.
FCef = 0 + 0 + 0 + 0 = 0
FCh2 = 1 + 0 + 1 + 0 = 2
Page 194
rate cir 10 pir 100
rate cir 10 pir 10
be
create
meter
3
broadcast-meter 2
multicast-meter 4
create
meter
3
broadcast-meter 2
create
meter
3
broadcast-meter 2
create
meter 5
broadcast-meter 4
multicast-meter 4
unknown-meter 4
1
create
match dot1p
7
action fc af
create
match dot1p 5
action fc l1
create
match dot1p
6
action fc h2
create
match dot1p 3
action fc h1
7210 SAS D, E OS Quality of Service Guide