Line differential protection RED670
Pre-configured
Product version: 1.1

2. Available functions

ANSI
Function description
Differential protection
(Only one alternative can be selected)
87
1 phase High impedance
differential protection
(HZPDIF)
87L
Line differential protection, 3
CT sets, 2-3 line ends (L3CPDIF)
87L
Line differential protection, 6
CT sets, 3-5 line ends (L6CPDIF)
87LT
Line differential protection 3
CT sets, with in-zone
transformers, 2-3 line ends
(LT3CPDIF)
87LT
Line differential protection 6
CT sets, with in-zone
transformers, 3-5 line ends
(LT6CPDIF)
Impedance protection
21
Distance protection zones,
quadrilateral characteristic
(ZMQPDIS/ZMQAPDIS)
Directional impedance
quadrilateral (ZDRDIR)
21
Distance measuring zone,
quadrilateral characteristic for
series compensated lines
(ZMCPDIS/ZMCAPDIS)
21
Directional impedance
quadrilateral, including series
compensation (ZDSRDIR)
21
Full-scheme distance
protection, mho characteristic
(ZMHPDIS)
Directional impedance element
for mho characteristic
(ZDMRDIR)
Additional distance protection
directional function for earth
faults (ZDARDIR)
Mho impedance supervision
logic (ZSMGAPC)
78
Power swing detection
(ZMRPSB)
Power swing logic (ZMRPSL)
78
Pole slip protection (PSPPPAM)
Automatic switch onto fault
logic, voltage and current
based (ZCVPSOF)
Current protection
50
Instantaneous phase
overcurrent protection
(PHPIOC)
6
Single breaker, 3-
Multi breaker, 3-
phase tripping
phase tripping
(A31)
(B31)
Basic
Option
Basic
Option
(Qty/
(Qty/
option
option
design)
design)
-
3/A02
-
3/A02
1
-
-
-
-
1/A04
1
-
-
1/A05
-
-
-
1/A06
-
1/A06
-
3/B01
-
3/B01
-
1/B01
-
1/B01
-
3/B06
-
3/B06
-
1/B06
-
1/B06
-
3/B07
-
3/B07
-
1/B07
-
1/B07
-
1/B07
-
1/B07
-
1/B07
-
1/B07
-
1/B01/
-
1/B01/
B06/B07
B06/B07
-
1/B03
-
1/B03
-
1/B21
-
1/B21
-
1/B01/
-
1/B01/
B06/B07
B06/B07
1
-
1
-
1MRK 505 188-BEN C
Issued: June 2010
Singel breaker, 1-
Multi breaker, 1-
phase tripping
phase tripping
(A32)
(B32)
Basic
Option
Basic
Option
(Qty/
(Qty/
option
option
design)
design)
-
3/A02
-
3/A02
1
-
-
-
-
1/A04
1
-
-
1/A05
-
-
-
1/A06
-
1/A06
-
1/B10,3/
-
3/B01
B01
-
1/B01
-
1/B01
-
3/B06
-
3/B06
-
1/B06
-
1/B06
-
3/B07
-
3/B07
-
1/B07
-
1/B07
-
1/B07
-
1/B07
-
1/B07
-
1/B07
-
1/B01/
-
1/B01/
B06/B07
B06/B07
-
1/B03
-
1/B03
-
1/B21
-
1/B21
-
1/B01/
-
1/B01/
B06/B07
B06/B07
1
-
1
-
ABB

Hide quick links:

Advertisement