Ketra X2 Installation Manual

Mesh keypad 120-277v; mesh + 600w incandescent dimmer 120v
Hide thumbs Also See for X2:

Advertisement

X2
I N S TA L L AT I O N G U I D E
Supported models:
X2-ND - KetraNet Mesh Keypad 120-277V
X2-INC - KetraNet Mesh + 600W Incandescent Dimmer 120V
*Available in multiple colors. Refer to specifications sheet.

Advertisement

Table of Contents
loading

Summary of Contents for Ketra X2

  • Page 1 I N S TA L L AT I O N G U I D E Supported models: X2-ND - KetraNet Mesh Keypad 120-277V X2-INC - KetraNet Mesh + 600W Incandescent Dimmer 120V *Available in multiple colors. Refer to specifications sheet.
  • Page 2 WAR N I N G Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker or remove fuse. Damage to this product caused by wiring with power on voids the warranty. Due to risk of electric shock, a licensed electrician should install this power supply unit in strict compliance with the National Electric Code and any state or local code which may apply.
  • Page 3: Table Of Contents

    TA B LE O F CO NTE NT S Product Overview............................... page 4 Included Components / Specs.......................... page 5 Dimension Drawings............................page 6 Dimmer Load............................... page 7 Wiring Diagrams..............................page 8 Installation................................page 10 Replacing Button Chassis..........................page 16 Operation................................page 17 Warranty &...
  • Page 4: Product Overview

    Mesh controller with onboard incandescent dimmer. The latter is ideal for spaces where both Ketra and traditional lighting sources need to be controlled. Fitting within a standard wall box and either Decora® or Claro wall plates, the X2 is perfect for retrofit installations as well as new construction.
  • Page 5: Included Components / Specs

    Storage Temperature -20° to 80°C Humidity 0-95%, Non-condensing Electrical Input Wiring 16 AWG Flying Leads Certification UL, cUL, FCC Class B, RoHS Voltage X2.ND 120-277 VAC Location UL Damp location, IP20 X2.INC 120VAC Power Consumption Mechanical Frequency 50/60 Hz Weight 8.8oz/250kg...
  • Page 6: Dimension Drawings

    CHECKED BY: SCALE: DRAWING TYPE: SCALE: 775-000015-02 DRAWING #: REVISION #: SHEET NAME DATE: 07/21/2016 X2 K X2 KEYPAD - PRO DRAWN BY: DL, CEH DOCUMENT DRA CHECKED BY: SCALE: PROPRIETARY SHEET NAME SHEET PROPRIETARY THE INFORMATION CONTAINED IN THIS...
  • Page 7: Dimmer Load

    DIMMER LOAD X2-INC Load Type and Capacity Chart Load Type Single Gang Multigang Incandescent 600W 500W Dimmer capacity rated at 25˚C ambient temperature; derate incandescent and halogen loads an additional 100W at 40˚C temperature ambient. PAGE 7 INSTALLATION GUIDE 770-000026-01 r08...
  • Page 8: Wiring Diagrams

    120V~ 50/60 HZ 50/60 HZ I N C Retrofit Installation * X2 and load on same circuit should be wired in parallel, not series. SWITCH - LOAD + SWITCH SWITCH - LOAD + SWITCH 3-Way Switch X2 Keypad Ketra Retrofit...
  • Page 9 WI R I N G D IAG R A M S LOAD - SPLIT SWITCHES 3-Way Switch LOAD - SPLIT SWITCHES X2 Keypad Ketra Retrofit I N C PAGE 9 INSTALLATION GUIDE 770-000026-01 r08...
  • Page 10: Installation

    4. Prepare the wire for connection to lead wire: A. Strip 8.5 mm of wire for insertion into the wire nut. B. Twist the stranded wire to prevent fraying (tinning optional). 5. Using the provided wire nuts, attach each X2 lead wire to the corresponding conductor. Black-Line, White- Neutral, Green-Ground. (See Fig 4)
  • Page 11 9. Secure Wall Plate Mount to the X2 using the supplied fasteners. (See Fig 6) Note: If the X2’s button chassis is not aligned with the wall plate mount, remove the mount and adjust the position of the X2. Secure the wall plate mount with the fasteners when satisfied.
  • Page 12 • The wall box should have a volume of 14 in3 or greater. • The X2 does not have to be on the same circuit as any Ketra fixtures, as all control signals are wireless. • Ketra fixtures to be controlled by the X2 should have an uninterrupted source of power. They should NOT be wired to a light switch or other intermediary device that could cut their power.
  • Page 13 (See Fig 1) Twist the stranded wire to prevent fraying (tinning optional). 4. Using the provided wire nuts, attach each X2 lead wire to the corresponding conductor. Black-Line, White-Neutral, Green-Ground, Red-Dimmed Line. (See Fig 2 & 3) Way light switches.
  • Page 14 8. Secure Wall Plate Mount to the X2 using the supplied fasteners. 8. Secure Wall Plate Mount to the X2 using the supplied fasteners. 8. Secure Wall Plate Mount to the X2 using the supplied fasteners. (See Fig 5) (See Fig 5)
  • Page 15 Ketra fixtures being controlled by the X2 Keypad. Ketra fixtures to be controlled by the X2 Keypad do not have to be connected to the same circuit, as the control signal is wireless. However, non-Ketra fixtures will need to be on the same circuit and wired in-line if they are to be controlled by an X2 with onboard incandescent dimmer.
  • Page 16: Replacing Button Chassis

    To replace the button chassis, follow these steps: 1. Pull airgap switch out. 2. (If X2 already installed) Snap the wall plate off of its mount, and then unscrew and remove the mount. Save screws. 3. Using a Phillips (PH1) screwdriver, unscrew the bottom-right screw that holds the button chassis in place.
  • Page 17: Operation

    OPERATION Status LEDs Highlight activated button. Keypad Buttons Press to activate or deactivate stored scenes or shows. Intensity Buttons Increase or decrease light intensity. Double tap up or down to go to the max/min intensity of the selected scene. Airgap Switch Pull out to disconnect power to device.
  • Page 18: Warranty & Tech Support

    WARRANTY & TECH SUPPORT Limited warranty terms can be found at: ketra.com/warranty For questions and technical support please contact: (512) 872-4357 support@ketra.com PAGE 18 INSTALLATION GUIDE 770-000026-01 r08...
  • Page 19 6321 E. Stassney Ln. Suite 400 ketra.com Austin, TX 78744 (512) 347-1100...

This manual is also suitable for:

X2-ndX2-inc

Table of Contents