Retrofit Important Notes:
• This wiring scheme is for standard in-line dimmer.
• Wall box should have volume of 14 in3 or greater.
• The X2 Keypad and Ketra products require a constant, uninterrupted source of electricity. Power needs
to be run directly to Ketra fixtures being controlled by the X2 Keypad. Ketra fixtures to be controlled by
the X2 Keypad do not have to be connected to the same circuit, as the control signal is wireless. However,
non-Ketra fixtures will need to be on the same circuit and wired in-line if they are to be controlled by
an X2 with onboard incandescent dimmer.
• For a dimmer retrofit installation using incandescent loads, the incoming and outgoing line connections
should NOT be tied together. Instead, the incoming line should be tied to the X2's black line wire, while
the outgoing line is tied to the X2's red dimmed-line wire. Refer to page 8's "X2 Keypad: Incandescent
Dimmer" wiring diagram for an illustration of the proper wiring.
1. Turn off power feed to the switch to be replaced.
2. Remove existing switch.
3. Continue with step 3 in the New Construction section for the non-dimming model, Page 10.