Dometic RTX1000 Operating Manual page 22

Coolair parking cooler
Hide thumbs Also See for RTX1000:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Display messages
8.2
Control panel fault messages
The "ERROR" symbol (fig. 4 5, page 4) lights up if there is a fault with the parking
cooler. The type of error is shown on the display by the following error codes:
Display
Description
text
F01
The compressor does not
work.
F02
F03
F04
The condensor fan 1 does
not work.
F05
The condensor fan 1 is
overloaded.
F06
The condensor fan 2 does
not work.
F07
The condensor fan 2 is
overloaded.
F08
The evaporator fan does
not work.
F09
The evaporator fan is
overloaded.
F10
F11
The system cannot
determine the internal
temperature.
F12
22
Cause
Error in compressor sensor
electrical supply (open
circuit).
Error in compressor sensor
electrical supply (short
circuit).
Compressor overload
No response from the fan.
Faulty fan speed
No response from the fan.
Faulty fan speed
No response from the fan.
Faulty fan speed
Error in temperature sensor
electrical supply (open
circuit).
Error in temperature sensor
electrical supply (short
circuit).
CoolAir RTX1000, RTX2000
Remedy
➤ Switch off the system.
➤ Switch it on again after
30 minutes.
➤ If the fault occurs again,
contact an authorised
workshop.
EN