Raypak 260-401 Installation And Operating Instructions Manual page 21

Econopak water heaters type wh
Table of Contents

Advertisement

6. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas, STOP! Follow "B" in the safety information
above on this label. If you don't smell gas, go to the
next step.
7. Locate pilot mounted on the right side of the burner
drawer, right of first burner.
8. Turn knob on gas control counterclockwise
to "PILOT".
9. Push down and hold the red reset button in, imme-
diately light the pilot with a match. Continue to hold
down red reset button for about one minute after the
pilot is lighted. Release red reset button and it will
pop back up. Pilot should remain lighted. If it goes
out, repeat steps 4 through 8.
* If red reset button does not pop up when
released, STOP and immediately call your
service technician or gas supplier.
* If the pilot does not stay lit after several tries,
turn the gas control knob to "OFF" and call your
Service technician or gas supplier.
10. Stand to the side of the heater and turn the gas
control knob counterclockwise
11. Replace heater door.
12. Turn "ON" all electrical power to the heater.
13. Set the tankstat to the desired setting.
SYSTEM SHUT DOWN PROCEDURE
1. Set the tankstat to "OFF" or the lowest setting.
2. Turn off all electric switches to the heater.
3. Turn off all gas valves supplying gas to the heater.
Refer to operating instruction label on the heater.
4. Shut off the water supply to the heater piping
system loop.
5. Open drain valve on the tank to remove water from
the heater and the piping circuits.
FOR AUTOMATIC IGNITION MODELS.
Please read carefully and understand the following
safety information before operating the heater.
WARNING: If you do not follow these instructions ex-
actly, a fire or explosion may result causing property
damage, personal injury or loss of life.
A. This heater is equipped with an ignition device
which automatically lights the pilot. Do not try to
light the pilot by hand.
B. BEFORE OPERATING smell all around the heater
area for gas. Be sure to smell next to the floor
because some gases are heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a
• If you cannot reach your gas supplier, call the
C. Use only your hand to push in, move or turn the gas
control knob or lever. Never use tools. If the knob
or lever will not push in, move or turn by hand don't
try to repair it, call a qualified service technician.
Force or attempted repair may result in a fire or
explosion.
D. Do not use this heater if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the heater and to replace any part of
the control system and any gas control which has
been underwater.
FOR INTERMITTENT IGNITION (IID) WITH
HONEYWELL OR ROBERTSHAW GAS VALVE
to "ON".
1. STOP! Read the safety information above on this
label.
2. Set the tankstat on the lowest setting.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition device
which automatically lights the pilot. Do not try to
light the pilot by hand.
5. Remove heater door panel.
6. For Robertshaw Gas Valve: Turn gas control
knob clockwise
For Honeywell Gas Valve: Turn gas control knob
clockwise
against stop.
For Honeywell Gas Valve: (Models 400)
Push in gas control knob slightly and turn clockwise
to "OFF". Knob cannot be turned to "OFF"
unless knob is pushed in slightly. Do not force.
7. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas, STOP! Follow "B" in the safety information
previously stated. If you do not smell gas, go to the
next step.
8. For Robertshaw Gas Valve: Turn gas control
knob counterclockwise
GAS CONTROL
KNOB SHOWN
IN "ON" POSITION
21
neighbor's phone. Follow the gas supplier's
instructions.
fire department.
to "OFF".
to "OFF". Make sure knob rest
GAS INLET
to "ON".
Fig. #8080

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-260Wh-261Wh-330Wh-331Wh-400Wh-401

Table of Contents