Receiving Equipment; General Specifications - Raypak 185 Operating And Installation Instructions

For 85, 265, 335, 405 swimming pool and spa heaters and 181/182, 260/261, 330/331, 400/401 water heaters and boilers
Table of Contents

Advertisement

INSTALLATION, START-UP AND OPERATION

1. RECEIVING EQUIPMENT

On receipt of your equipment it is suggested that you visually check for external damage to the carton. If
the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment.
Remove the complete assembly from the carton if it is damaged report the damage to the carrier immediately.
Be sure that you receive the number of packages indicated on the Bill of Lading. Claims for shortages and
damages must be filed with the carrier by consignee.
Purchased parts are subject to replacement only under the manufacturer's warranty. Debits for defective
replacement parts will not be accepted and defective parts will be replaced in kind only per our standard
warranties.
When ordering parts, you must specify Model and Serial Number of the unit. When ordering under warranty
conditions, you must also specify date of Installation.
Raypak recommends that this manual be reviewed thoroughly before installing the D-2 Power Vent. If there
are any questions which this manual does not answer, please contact your local Raypak Representative.
THIS MANUAL SHOULD BE MAINTAINED IN LEGIBLE CONDITION AND KEPT ADJACENT TO THE UNIT.

2. GENERAL SPECIFICATIONS

The D-2 Power Vent Assembly is tested and certified to the latest edition of the American National Standard
ANSI Z21.56. standard for pool heaters, Z21.10.3 for water heaters and Z21.13 for boilers.
The Power Vent Assembly is a fan assisted combustion system designed for application to Raypak Pool
Heater Models 185-405. The unit, when installed as directed, is capable of operating in applications such as
through the wall venting and reduced horizontal and vertical vent pipe sizes in new and existing installations.
The D-2 Power Vent assembly includes a blower with a 120/240 volt 60 Hz 1.0/1.95A 3200 RPM motor, a
plenum complete with a draft proving switch and a motor relay. When provided for field mounting the assembly
is equipped with a wire harness.
MODEL
SIZE
185
265
335
405
182/181
260/261
330/331
400/401
POWER VENT ASSEMBLY
MINIMUM
CONNECTION
DIAMETER
4"
4"
4"
4"
4"
4"
4"
4"
2
KIT
FACTORY
NUMBER
WIRED
008086
240V
008086
240V
008087
240V
008087
240V
008757
120V
008757
120V
008758
120V
008758
120V