CLEARANCES

WARNING: The heater shall not be located in an area where water sprinklers, or other devices, may cause water
to spray through the cabinet louvers and into the heater. This could cause heavy internal rusting or damage some
electrical components, and this would void the warranty.
ALL HEATERS
For clearances from combustible surfaces, see the following chart.
CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
INDOOR INSTALLATION
Top*(Drafthood) -
Vent - 6"
Back-12"
*Clearance from Top of Vent Terminal.
For servicing, provide at least 24" in front of the heater for burner tray removal, and at least 18" on the back of the
heater to inspect and delime the heat exchanger.
OUTDOOR HEATERS
These heaters are design certified for outdoor installation, when equipped with the approved tops designated
for outdoor use.
HEATER WITH OUTDOOR
STACKLESS TOP
WARNING: Do not install within 3 feet of a Heat Pump or an outdoor condensing unit. Strong air intake from
this equipment can disturb the combustion process and cause damage or personal injury.
42"
Right Side - 6"
Left Side - 12"
Front - Alcove
OUTDOOR INSTALLATION
Top *(Stackless Top or Outdoor Stack) - Unobstructed
Back - 12"
Sides - 6"
Fig# 8116
10

Hide quick links:

Advertisement