EP30006
10.15.4. Removing the Width sensor
1.
Disconnect all the Connectors on the Main PCB.
2.
Cut the Insulated ties bundling the Lead wires.
3.
Unscrew four Screws on the Main PCB install plate.
4.
Cut three Insulated ties on the Width sensor install plate.
5.
Unscrew two Screws on the Width sensor install plate.
Be sure to allocate Hoses as the figure.
6.
Remove one Snap pin installing the Sensor plate.
Caution in assembly
- When fixing the Lead wires with Insulated ties, move the
Massage mechanism block in the directions of strong-weak so
as to check whether the Lead wires are pulled or hooked.
- 40 -