1. STOP! Read the safety information.
2. Set the thermostat to the lowest setting.
3. Turn off all electrical power to the boiler.
4. Push in and move gas control lever counter-
clockwise
GAS CONTROL
LEVER SHOWN
IN "OFF" POSITION

GAS INLET

5. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas, STOP! Follow "B" in the safety information on
the label affixed to the unit. If you don't smell gas, go
to the next step.
6. Locate pilot mounted on the right side of the
burner tray, and right of first burner.
HONEYWELL PILOT
7. Move control lever clockwise
position and immediately light pilot with a match.
8. Hold lever in "SET" position for 1/2 minute after
pilot is lit. Release lever, and it will spring back
to "PILOT" position. Pilot should remain lit. If it
goes out, repeat steps 4 through 8.
to "OFF" position.
ROBERTSHAW PILOT
to "SET"
*If lever does not spring back to "PILOT" position
when released, stop and immediately call your
service technician or gas supplier.
*If the pilot does not stay lit after several tries,
move the gas control lever to "OFF" and call your
service technician or gas supplier.
9. Stand to the side of the boiler and move the gas
control lever counter-clockwise
1. Set the thermostat to the lowest setting.
2. Turn off all electrical power to the boiler
3. Push in and move gas control lever counter-
clockwise
to "OFF" position. Do not force.
to "ON".