IntesisBox FJ-RC-MBS-1 User Manual page 22

Modbus rtu (eia-485) interface for fujitsu air conditioners.
Hide thumbs Also See for FJ-RC-MBS-1:
Table of Contents

Advertisement

157
39
158
3A
165
41
166
42
167
43
168
44
169
45
170
46
171
47
172
48
173
49
181
51
182
52
183
53
184
54
185
55
186
56
187
57
188
58
189
59
195
5U
197
61
198
62
199
63
200
64
201
65
202
66
203
67
204
68
205
69
206
6A
213
71
214
72
215
73
216
74
217
75
218
76
219
77
220
78
229
81
230
82
231
83
232
84
233
85
234
86
235
87
245
91
246
92
247
93
248
94
249
95
250
96
251
97
© Intesis Software S.L.U. - All rights reserved
This information is subject to change without notice
IntesisBox
®
is a registered trademark of Intesis Software SLU
FJ-RC-MBS-1
Indoor unit power supply circuit error
Indoor
controller) error
Indoor unit room temp. thermistor error
Indoor unit heat ex. temp. thermistor error
Humidity sensor error
Light sensor error
Gas sensor error
Float sensor error
Water temperature sensor error
Warm water flow rate sensor error
Heater sensor error
Indoor unit fan motor 1 error
Indoor unit coil (expansion valve) error
Indoor unit water drain abnormal
Air cleaning function error
Filter cleaning function error
Water circulation pump error
Indoor unit damper error
RAC
Indoor unit intake grille position error
Inverter
Indoor unit fan motor 2 error
Models G
Indoor unit miscellaneous error
series
Outdoor unit power supply abnormal
Outdoor unit main PCB error
VRF
Outdoor unit inverter PCB error
J-II/V-
Outdoor unit active filter/PFC circuit error
II/VR-II
Series
Outdoor unit IPM error
Convertor distinction error
Outdoor unit power short interruption error (protective
operation)
Outdoor unit magnetic relay error
Outdoor unit transmission PCB error
Outdoor unit display PCB error
Outdoor unit discharge temp. thermistor error
Outdoor unit compressor temp. thermistor error
Outdoor unit heat ex. temp. thermistor error
Outside air temp. thermistor error
Outdoor unit suction gas temp. thermistor error
Outdoor unit operating valve thermistor error
Outdoor unit heat sink temp. thermistor error
Expansion valve temperature sensor error
Receiver liquid level detection sensor error
Outdoor unit sub-cool heat ex. gas temp. thermistor error
Outdoor unit liquid pipe temp. thermistor error
RAC
Outdoor unit current sensor error
Inverter
Fan motor current sensor error
Models G
Outdoor unit pressure sensor error
series
Oil sensor error
Outdoor unit compressor 1 error
Outdoor unit compressor 2 error
VRF
Outdoor unit compressor start up error
J-II/V-
Outdoor unit trip detection
II/VR-II
Series
Outdoor unit compressor motor control error
Open loop error(Field-weakening relevant)
Outdoor unit fan motor 1 error
unit
communication
URL
http://www.intesisbox.com
Email
info@intesisbox.com
Phone
+34 938047134
User's Manual r1.9 EN
circuit
(wired
remote
22/24

Advertisement

Table of Contents
loading