Error
Description
code
Transmission buffer
81
error
82
Connection lost
Read the safety information
in section 3 carefully before
working with the sensor.
1HSA 801 080-15en EXCOUNT-II Users Manual
10. Transceiver error codes
Suggested cause and action
The transceiver registred a buffer error. Turn
off the transceiver and restart. Attempt with
individual readings rather than total reading
(if this was the case). If the error persists,
a serious internal fault may have occured.
Contact your EXCOUNT-II service represen-
tative.
The sensor recognised its ID but the con-
nection was lost during the transmission.
Wait 30 seconds before re-transmiting again.
If the error persists, check:
a) the distance and orientation to the sensor
is as described in section 4.
b) interference from a high frequency source
c) battery status to ensure the transceiver-
battery voltage is sufficient.
d) antenna status to ensure it is correctly
enabled.
Note! If none of the above are found to be
the cause, then consider the following:
When the energy in the sensor falls below a
certain level, the sensor switches off the liste-
ning function (to conserve energy for recor-
ding) until such time that the energy level
is sufficient again for communication. This
may occur if many attempts to communicate
have been made in a row or because there
is insufficient sunlight and/or electrical field.
Should unexplained difficulties occur during
communication, it is suggested to wait until
another time to make measurements or else
install a 9V battery in the sensor.