• Replace the fi lter support
• Screw the fi lter support using the 2 screws 12c (2,9 x 6 ,5) pro-
vided.
• Replace the grease fi lters make sure that the handle is visible on
the outside.
When installing the ducted version, connect the hood to the chimney using either a fl exible or rigid
pipe ø 150 or 120 mm, the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection,
insert the reducer fl ange 9 on the hood body
outlet.
• Fix the pipe in position using suffi cient pipe
clamps (not supplied).
• Remove any activated charcoal fi lters.
• Drill a hole ø 120 or 150 mm in the shelf above the hood
and connect the hood canopy outlet to the top part of
the wall unit by means of a rigid or fl exible pipe of the
same diameter, the choice of which is at the discretion
of the installer.
• To install a ø 120 mm air exhaust connection, insert the
reducer fl ange 9 on the hood body outlet.
• Fix the pipe in position using suffi cient pipe clamps (not
supplied).
• Ensure that the activated charcoal fi lters have been
inserted.
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3
mm.
GB
Connections
DUCTED VERSION AIR EXHAUST SYSTEM

RECIRCULATION VERSION AIR OUTLET

ELECTRICAL CONNECTION

15