INSTALLATION MANUAL

FULL-CASED MULTI-POSITION FOR
COOLING/HEAT PUMPS
MODELS: MC
FULL-CASED UPFLOW/COUNTERFLOW FOR
COOLING/HEAT PUMPS
MODELS: FC
PARTIAL-CASED UPFLOW FOR COOLING/HEAT PUMP
MODELS: PC
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
COIL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DUCT CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Component Location - Coil MC & FC . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Component Location - Coil PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
TXV Bulb Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Proper Bulb Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Duct Flanges - Coil FC/MC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Vertical Applications with Furnaces . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Horizontal Right Application with Furnaces . . . . . . . . . . . . . . . . . . . . . 5
Horizontal Left Application with Furnaces . . . . . . . . . . . . . . . . . . . . . . 5
Dimensions - MC Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Dimensions - FC Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dimensions - PC Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION I: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicated a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to alert
against unsafe practices and hazards involving only property damage.
WARNING
!
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to this manual for assis-
tance or additional information, consult a qualified installer or service
agency.
LIST OF SECTIONS
CONDENSATE DRAIN CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . 6
REFRIGERANT LINE CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . 7
COIL CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
AIR SYSTEM ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
INSTALLATION VERIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
LIST OF FIGURES
Upflow - PC Coil Installation with Furnace . . . . . . . . . . . . . . . . . . . . . 5
Condensate Deflector on Vertical Drain Pan . . . . . . . . . . . . . . . . . . . 6
S-Clip Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Pressure Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
TXV Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Drain Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
LIST OF TABLES
Coil Air Flow Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Coil Projection Dimensions - PC Coils . . . . . . . . . . . . . . . . . . . . . . . . 5
Air Flow Data - Static Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . 7
This product must be installed in strict compliance with the enclosed
installation instructions and any applicable local, state, and national
codes including, but not limited to building, electrical, and mechanical
codes.
The furnace area must not be used as a broom closet or for any other
storage purposes, as a fire hazard may be created. Never store items
such as the following on, near or in contact with the furnace.
1. Spray or aerosol cans, rags, brooms, dust mops, vacuum
cleaners or other cleaning tools.
2. Soap powders, bleaches, waxes or other Cleaning com-
pounds; plastic items or containers; gasoline, kerosene, ciga-
rette lighter fluid, dry cleaning fluids or other volatile fluid.
3. Paint thinners and other painting compounds.
4. Paper bags, boxes or other paper products
Never operate the furnace with the blower door removed. To do so
could result in serious personal injury and/or equipment damage.
CAUTION
!
WARNING
!
5353649-UIM-A-0617
ISO 9001
Certified Quality
Management System

Advertisement

Table of Contents
loading

Summary of Contents for York MC18A

  • Page 1: Table Of Contents

    INSTALLATION MANUAL FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: MC FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS MODELS: FC PARTIAL-CASED UPFLOW FOR COOLING/HEAT PUMP ISO 9001 Certified Quality Management System MODELS: PC LIST OF SECTIONS SAFETY ..........1 CONDENSATE DRAIN CONNECTIONS .
  • Page 2: General Information

    Distributor for more information. Check drain pan for cracks or break- age. TABLE 1: Dimensions - MC Coils Refrigerant Dimensions Connections 20 3/8” Models Height Width Opening Widths Line Size (Opening) Liquid Vapor MC18A 14-1/2 13-3/8 13-1/2 MC18B 17-1/2 16-3/8 16-1/2 MC24A 26-1/2 14-1/2 13-3/8 13-1/2 MC24B 26-1/2...
  • Page 3: Dimensions - Fc Coils

    5353649-UIM-A-0617 TABLE 2: Dimensions - FC Coils Refrigerant Dimensions Connections Models Height Width Opening Widths Line Size Liquid Vapor 20-3/8” (Opening) FC18A 14-1/2 13-3/8 13-1/2 (Opening) FC18B 17-1/2 16-3/8 16-1/2 FC24A 14-1/2 13-3/8 13-1/2 FC24B 17-1/2 16-3/8 16-1/2 FC30A 14-1/2 13-3/8 13-1/2 FC30B...
  • Page 4: Coil Metering Devices

    5353649-UIM-A-0617 LIMITATIONS These coils should be installed in accordance with all national and local SCREW safety codes. TXV BULB TABLE 4: Coil Air Flow Limits (Cover completely with insulation) CFM Limits Coil Outdoor Unit Size Tons Minimum Maximum 1-1/2 1-1/2 30, 32 CLAMP 2-1/2...
  • Page 5: Vertical Applications With Furnaces

    5353649-UIM-A-0617 Furnace Furnace FIGURE 8: Horizontal Left Application with Furnaces FURNACE ASSEMBLY - PC The PC coils are designed for installation on top of upflow furnaces only. Furnace If the coil is used with a furnace of a different size, use a 45° transition to allow proper air distribution through the coil.
  • Page 6: Duct Connections

    5353649-UIM-A-0617 CRITICAL COIL PROJECTION CAUTION The coil assembly must be located in the duct such that a minimum dis- tance is maintained between the top of the coil and the top of the duct. Threaded drain connections should be hand tightened, plus no more Refer to Table 5.
  • Page 7: Refrigerant Line Connection

    5353649-UIM-A-0617 Lines should be sound isolated by using appropriate hangers or strap- Condensate ping. Deflector All evaporator coil connections are copper-to-copper and should be brazed with a phosphorous-copper alloy material such as Silfos-5 or equivalent. DO NOT use soft solder. Drain Pan SECTION VIII: COIL CLEANING Wall...
  • Page 8: Installation Verification

    (All other drain connections should be plugged) FIGURE 16: Location of Trapped and Plugged Drain Connections Subject to change without notice. Published in U.S.A. 5353649-UIM-A-0617 Copyright © 2017 by Johnson Controls, Inc. All rights reserved. Supersedes: 900588-UIM-C-0214 York International Corp. 5005 York Drive Norman, OK 73069...