Artesian Spas Grand Bahama Manual

Artesian Spas Grand Bahama Manual

Hide thumbs Also See for Grand Bahama:

Advertisement

WWW.ARTESIANSPAS.COM
Part # 11-0088-11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Grand Bahama and is the answer not in the manual?

Questions and answers

Summary of Contents for Artesian Spas Grand Bahama

  • Page 1 WWW.ARTESIANSPAS.COM Part # 11-0088-11...
  • Page 2 Captiva Nevis Bimini Santa Cruz Copyright 2008 May Mfg. LLC - All rights Reserved. This document may not be copied, photocopied, reproduced, translated or transmitted in any form or for any purposes without the express written consent of Artesian Spas.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Congratulations............Safety Warnings............Line Drawing Key............Spa Configuration and Specs........Pump Configurations..........Electrical Requirements and Installation....60Hz GFCI Wiring Schematic......50Hz Electrical Service Configuration Options.. Spa Start Up..............Selecting a Location.......... Inspection............Filling the Spa with Water........Turning the Power On........
  • Page 4 TABLE OF CONTENTS cont... Cleaning Your Spa Interior........Cover Care............. Chemical Treatment of Water......... Water Chemistry.............. Water Treatment Glossary........Spa Chemicals Glossary........Maintaining the Proper pH........Warranty Information............. Interior Spa Diagram............
  • Page 5: Congratulations

    Congratulations... Congratulations on the purchase of your new Island spa by Artesian. We know you will enjoy your spa. Although spas are relaxing and fun, we believe they can be an indispensable part of a healthy lifestyle. The spa lifestyle is one that encourages health and well-being.
  • Page 6 For your future reference and convenience, please record the Se- rial and Model number along with the installation date in the spaces provided below. STORE THIS MANUAL WHERE YOU CAN EAS- ILY FIND IT WHEN NEEDED. The serial and model numbers are mounted on the base of the equipment enclosure area, as shown below.
  • Page 7: Safety Warnings

    SAFETY WARNINGS PLEASE TAKE THE TIME TO READ ALL OF THESE WARNINGS AND CAUTIONS PRIOR TO USING YOUR SPA. PLEASE, be a responsible spa owner. When installing and using this spa, always adhere to basic safety precautions. Be sure to list emergency telephone numbers at the telephone nearest the spa, including physician, hospital, ambulance, police and the fire department.
  • Page 8 SAFETY WARNINGS cont... 8. WARNING - To reduce the risk of injury: a) The water in a spa should never exceed 40ºC (104ºF). Water tempera- tures between 38ºC (100ºF) and 40ºC are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes.
  • Page 9 AUDIO COMPONENT WARNINGS Spas equipped with the Audio system should follow these guide- lines for safety: 1. CAUTION - Risk of Electrical Shock - Do not leave compartment door open. 2. CAUTION - Risk of Electrical Shock - Replace components only with identical components.
  • Page 10: Line Drawing Key

    LINE DRAWING KEY Name of Component Symbol for Component Whirlpool 5in Helix Direct 5” Helix Roto 4.5” Helix Direct / Roto 4” Helix Jet 2.75in Helix Direct /3” Roto / Mssg Helix Direct 2” Jumbo Storm Massage Filter Speaker Diverter / Air Control Topside Control Line Drawings may not be exact models of your particular spa.Certain options may be shown that are not included on your spa.
  • Page 11: Spa Configuration And Specs

    SPA CONFIGURATION AND WATER CAPACITY GRAND BAHAMA 62-3P 60Hz 50Hz Volume 450 gal 1703 l Weight (dry/filled) 800/4551 lbs 363/2064 kg 91x91x36in 231x231x91 cm ensions Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional...
  • Page 12 SPA CONFIGURATION AND WATER CAPACITY GRAND BAHAMA 52 60Hz 50Hz Volume 450 gal 1703 l Weight (dry/filled) 800/4551 lbs 363/2064 kg 91x91x36in 231x231x91 cm ensions Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional...
  • Page 13 SPA CONFIGURATION AND WATER CAPACITY GRAND BAHAMA 44 60Hz 50Hz Volume 450 gal 1703 l Weight (dry/filled) 800/4551 lbs 363/2064 kg 91x91x36in 231x231x91 cm ensions Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional...
  • Page 14 SPA CONFIGURATION AND WATER CAPACITY GRAND BAHAMA 32-2P 60Hz 50Hz Volume 450 gal 1703 l Weight (dry/filled) 800/4551 lbs 363/2064 kg 91x91x36in 231x231x91 cm ensions Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional...
  • Page 15 SPA CONFIGURATION AND WATER CAPACITY GRAND BAHAMA 32 60Hz 50Hz Volume 450 gal 1703 l Weight (dry/filled) 800/4551 lbs 363/2064 kg 91x91x36in 231x231x91 cm ensions Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional...
  • Page 16 SPA CONFIGURATION AND WATER CAPACITY GRAND CAYMAN 62-3P 60Hz 50Hz Volume 475 gal 1798 l Weight (dry/filled) 800/4760 lbs 363/2159 kg 91x91x36in 231x231x91 cm ensions Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 17 SPA CONFIGURATION AND WATER CAPACITY GRAND CAYMAN 52 60Hz 50Hz Volume 475 gal 1798 l Weight (dry/filled) 800/4760 lbs 363/2159 kg 91x91x36in 231x231x91 cm ensions Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 18 SPA CONFIGURATION AND WATER CAPACITY GRAND CAYMAN 44 60Hz 50Hz Volume 475 gal 1798 l Weight (dry/filled) 800/4760 lbs 363/2159 kg 91x91x36in 231x231x91 cm ensions Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 19 SPA CONFIGURATION AND WATER CAPACITY GRAND CAYMAN 32-2P 60Hz 50Hz Volume 475 gal 1798 l Weight (dry/filled) 800/4760 lbs 363/2159 kg 91x91x36in 231x231x91 cm ensions Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 20 SPA CONFIGURATION AND WATER CAPACITY GRAND CAYMAN 32 60Hz 50Hz Volume 475 gal 1798 l Weight (dry/filled) 800/4760 lbs 363/2159 kg 91x91x36in 231x231x91 cm ensions Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 21 SPA CONFIGURATION AND WATER CAPACITY CAPTIVA 52-2P 60Hz 50Hz Volume 400 gal 1514 l Weight (dry/filled) 730/4064lbs 331/1844 kg Dimensions 84x84x36in 213x213x91 cm Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 22 SPA CONFIGURATION AND WATER CAPACITY CAPTIVA 44 60Hz 50Hz Volume 400 gal 1514 l Weight (dry/filled) 730/4064lbs 331/1844 kg Dimensions 84x84x36in 213x213x91 cm Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 23 SPA CONFIGURATION AND WATER CAPACITY CAPTIVA 32-2P 60Hz 50Hz Volume 400 gal 1514 l Weight (dry/filled) 730/4064lbs 331/1844 kg Dimensions 84x84x36in 213x213x91 cm Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 24 SPA CONFIGURATION AND WATER CAPACITY CAPTIVA 32-1P 60Hz 50Hz Volume 400 gal 1514 l Weight (dry/filled) 730/4064lbs 331/1844 kg Dimensions 84x84x36in 213x213x91 cm Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 25 SPA CONFIGURATION AND WATER CAPACITY CAPTIVA 22 60Hz 50Hz Volume 400 gal 1514 l Weight (dry/filled) 730/4064lbs 331/1844 kg Dimensions 84x84x36in 213x213x91 cm Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 26 SPA CONFIGURATION AND WATER CAPACITY ANTIGUA 52 60Hz 50Hz Volume 375 gal 1419 l Weight (dry/filled) 730/3856lbs 331/1749 kg Dimensions 84x84x36in 213x213x91 cm Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 27 SPA CONFIGURATION AND WATER CAPACITY ANTIGUA 44 60Hz 50Hz Volume 375 gal 1419 l Weight (dry/filled) 730/3856lbs 331/1749 kg Dimensions 84x84x36in 213x213x91 cm Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 28 SPA CONFIGURATION AND WATER CAPACITY ANTIGUA 32-2P 60Hz 50Hz Volume 375 gal 1419 l Weight (dry/filled) 730/3856lbs 331/1749 kg Dimensions 84x84x36in 213x213x91 cm Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 29 SPA CONFIGURATION AND WATER CAPACITY ANTIGUA 32-1P 60Hz 50Hz Volume 375 gal 1419 l Weight (dry/filled) 730/3856lbs 331/1749 kg Dimensions 84x84x36in 213x213x91 cm Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 30 SPA CONFIGURATION AND WATER CAPACITY ANTIGUA 22 60Hz 50Hz Volume 375 gal 1419 l Weight (dry/filled) 730/3856lbs 331/1749 kg Dimensions 84x84x36in 213x213x91 cm Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 31 SPA CONFIGURATION AND WATER CAPACITY BIMINI 72 60Hz 50Hz Volume 580 gal 2195 l Weight (dry/filled) 1200/6035 lbs 544/2737 kg Dimensions 91x132x36 in 335x231x91 cm Control MVS504DZ MGS504DZ Heater 5.5kW Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 32 SPA CONFIGURATION AND WATER CAPACITY NEVIS 42 60Hz 50Hz Volume 310 gal 1173 l Weight (dry/filled) 680/3264 lbs 308/1481 kg Dimensions 84X78X34 in 213X198X86 cm Control MVS504DZ MGS504DZ Heater 5.5kw Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 33 SPA CONFIGURATION AND WATER CAPACITY NEVIS 32-2P 60Hz 50Hz Volume 310 gal 1173 l Weight (dry/filled) 680/3264 lbs 308/1481 kg Dimensions 84X78X34 in 213X198X86 cm Control MVS504DZ MGS504DZ Heater 5.5kw Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 34 SPA CONFIGURATION AND WATER CAPACITY NEVIS 32-1P 60Hz 50Hz Volume 310 gal 1173 l Weight (dry/filled) 680/3264 lbs 308/1481 kg Dimensions 84X78X34 in 213X198X86 cm Control MVS504DZ MGS504DZ Heater 5.5kw Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 35 SPA CONFIGURATION AND WATER CAPACITY SANTA CRUZ 30-2P 60Hz 50Hz Volume 225 gal 852 l Weight (dry/filled) 500/2376 lbs 227/1078 kg Dimensions 84x61x32 in 208x152x81 cm Control MVS504DZ MGS504DZ Heater 5.5kw Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 36 SPA CONFIGURATION AND WATER CAPACITY SANTA CRUZ 30-1P 60Hz 50Hz Volume 225 gal 852 l Weight (dry/filled) 500/2376 lbs 227/1078 kg Dimensions 84x61x32 in 208x152x81 cm Control MVS504DZ MGS504DZ Heater 5.5kw Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 37 SPA CONFIGURATION AND WATER CAPACITY SANTA CRUZ 18 60Hz 50Hz Volume 225 gal 852 l Weight (dry/filled) 500/2376 lbs 227/1078 kg Dimensions 84x61x32 in 208x152x81 cm Control MVS504DZ MGS504DZ Heater 5.5kw Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 38 SPA CONFIGURATION AND WATER CAPACITY SANTA CRUZ 13 60Hz 50Hz Volume 225 gal 852 l Weight (dry/filled) 500/2376 lbs 227/1078 kg Dimensions 84x61x32 in 208x152x81 cm Control MVS504DZ MGS504DZ Heater 5.5kw Flo-Thru 2.0kW Flo-Thru Circulation System optional optional Ozone optional optional Cartridge Filter...
  • Page 39: Pump Configurations

    Pump Configuration for 60Hz Model Type Pump 1 Pump 2 Pump 3 62-3P 3MBHP- 1SP 230V 6MBHP-2SP 230V 6MBHP-1SP 230V 52-2P 44-2P 4.8MBHP 230V 4.8MBHP-1SP 230V 32-1P 6MBHP-2SP 230V 32-2P 3MBHP-1SP 230V 3MBHP-3SP 230V 52-2P 6MBHP-1SP 230V 6MBHP-2SP 230V 4.8MBHP-1SP 230V 4.8MBHP-2SP 230V 44-2P 6MBHP-2SP 230V...
  • Page 40 Pump Configuration for 50Hz Model Type Pump 1 Pump 2 Pump 3 62-3P 1.4HP-1SP 230V 2HP-2SP 230V 3HP-1SP 230V 52-2P 44-2P 32-2P 1.4HP-1SP 230V 1.4HP-1SP 230V 32-1 2HP-2SP 230V 1.4HP-1SP 230V 2HP-2SP 230V 3HP-1SP 230V 52-2P 44-2P 32-2P 1.4HP-1SP 230V 1.4HP-1SP 230V 32-1P 2HP-2SP 230V 22-1P...
  • Page 41: Electrical Requirements And Installation

    48 amp input. This feature gives you the most performance out of your spa. This will require a 240V, 60-amp GFCI If a 60-amp service is not available, please contact the Artesian Spas’ Customer Service Depart- ment to configure the amp draw requirements.
  • Page 42 Picture of System Box Terminal Connection for 60Hz 240/120 VAC SERVICE 240VAC SERVICE CLASS G FUSE 30A CLASS G FUSE 30A WHT AC WHT AC J25 J63 J25 J63 NEUTRAL (WHITE) NEUTRAL (WHITE) FUSE .3A 250V HOT (BLACK) LINE 1 HOT (BLACK) LINE 1 HOT (RED) LINE 2 TORQUE...
  • Page 43: 60Hz Gfci Wiring Schematic

    60 Hz GFCI Wiring Schematic...
  • Page 44: 50Hz Electrical Service Configuration Options

    50 Hz Electrical Service Configuration Options Single Service, TN and TT Electrical Systems (1 X 16 Amp or 1 X 32 Amp) 3 Wires (1 Line + 1 Neutral + 1 Protective Earth) Protective Earth wire (Green / Yellow) must be connected to system ground terminal as marked.
  • Page 45 50 Hz Electrical Service Configuration Options Dual Service, TN and TT Electrical Systems (2 x 16 Amp) 5 Wires (2 Lines + 2 Neutrals + 1 Protective Earth) Protective Earth wire (Green / Yellow) must be connected to system ground terminal as marked.
  • Page 46 50 Hz Electrical Service Configuration Options 3-Phase Service, TN and TT Electrical Systems (3 x 16 Amp) 5 Wires (3 Lines + 1 Neutral + 1 Protective Earth) Protective Earth wire (Green / Yellow) must be connected to system ground terminal as marked. IMPORTANT - Service MUST include a neutral wire, with a line neutral voltage of 230VAC.
  • Page 47 50 Hz Electrical Service Configuration Options Single Service, IT Electrical System (No Neutral) Line - Line voltage is 230VAC (1 X 16 Amp or 1 X 32 Amp) 3 Wires (2 Lines + 1 Protective Earth) Protective Earth wire (Green / Yellow) must be connected to system ground terminal as marked.
  • Page 48 50 Hz Electrical Service Configuration Options 3 Phase Service, IT Electrical System (No Neutral) Line - Line voltage is 230VAC 4 Wires (3 Lines + 1 Protective Earth) Protective Earth wire (Green / Yellow) must be connected to system ground terminal as marked.
  • Page 49: Spa Start Up

    SPA START-UP Please read each step of the Start-up section prior to doing the step. SELECTING A LOCATION In preparation for installing your new Artesian spa, you should en- sure that your chosen location meets some minimum guidelines: 1) Place your spa on a surface that is large enough for the entire spa to fit.
  • Page 50: Inspection

    7) Have the spa deck installed by a knowledgeable contractor to ensure proper support. 8). If the spa is placed on the ground, even for a short period of time, it must be supported by stones that are at least 2 inches thick and 12 inch- es square.
  • Page 52: Testing The Gfci Breaker

    TESTING THE GFCI BREAKER NOTE: The electrical service panel for your spa should be equipped with a GFCI breaker. To avoid the risk of electrical shock, perform the following safety test before each use of your spa. 1) Make sure the power is turned on at the electrical service panel. 2) Turn on the GFCI breaker.
  • Page 53: Priming The Pump

    SPA START-UP cont... Turning on the Spa for the first time. NOTE: When power is turned on, your spa will automatically start out in priming mode for approximately 2 minutes indicated by “Pr” on the topside control. During this time no components are powered. At the end of the two minute period the low speed pump will be activated for 30 seconds followed by all of the pumps being activated on high speed for another 30 seconds.
  • Page 54: Topside Controller Instructions

    Topside Controller Instructions Initial Start up / Setting the Time of Day Topside control for Island models After the spa has been powered up and the topside controller is finished displaying “Pr”, the user may control the various pumps, lights, temperature of the water, filter cycles, and choose between different modes of operation from this topside controller.
  • Page 55: Light

    Light/ Mode/ Jets Light Press the “Light” button to turn the light on and off. If left on, the light automatically turns off after 4 hours. Mode The mode is changed by pressing the up or down arrow then the mode key.
  • Page 56: Preset Filter Cycles

    Topside Controller Instructions cont... Preset Filter Cycles/ Optional Filter Cycles Preset Filter Cycles The first filter cycle is automatically activated at 8:00 am and oper- ates the low speed of pump one* (or the circulation pump if spa is equipped) until 10:00 am. The second filter cycle is automatically activated at 8:00 p.m.
  • Page 57: Temperature Set

    Topside Controller Instructions cont... Temp/Set (80°F - 104°F / 26°C - 40°C)/ Freeze Protection Temp/Set (80°F - 104°F / 26°C - 40°C) The start-up temperature is set to 100°F/37°C. The Last measured temperature is constantly displayed on the LCD. NOTE: The last measured spa temperature displayed is current only when the pump has been running for at least 1 minute.
  • Page 58: Diagnostic Messages

    Diagnostic Messages Temperature unknown. After the pump has been running for 2 minutes, the temperature will be displayed “Overheat” - The spa has shut down. One of the sensors has detected 118°F/48°C at the heater. DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool.
  • Page 59 Diagnostic Messages cont... Sensors are out of balance. If alternating with spa temperature, it may just be a temporary condition. If flashing by itself, spa is shut down. If the problem persists, contact your dealer or service organization. A significant difference between temperature sensors has been detected.
  • Page 60: Maintaining Your Spa

    MAINTAINING YOUR SPA DRAINING YOUR SPA Your spa needs to be drained, cleaned, waxed, and refilled about every six months. More frequent water changes may be necessary if bather load is heavy. A hose bib has been provided below the left side of your front access panel, to assist you in draining your spa.
  • Page 61: Jet Care

    JET CARE We recommend that you clean your jets when you drain your spa. 1) Spray jet inserts with a mixture of 1 part vinegar to two parts warm water and let soak for 10 - 15 minutes. Pe- riodically rotate the spinner nozzle to break up residue in the jets.
  • Page 62: Removing, Installing And Cleaning Filters

    MAINTAINING YOUR SPA cont... REMOVING, INSTALLING AND CLEANING FILTERS These are the steps needed to successfully replace your filters. You should replace your disposable spa filters and clean your non dispos- able filters every four months. 1) Turn off all power to your spa and remove the filter lid by lifting it out towards you.
  • Page 63: Winterizing Your Spa

    WINTERIZING YOUR SPA It is not recommended that you drain your spa completely during freez- ing conditions. We recommend that you leave your spa full of water with the power on to keep the tub from freezing. If you decide to drain your spa during freezing conditions, contact your dealer for help.
  • Page 64: Spa Cabinet Care

    MAINTAINING YOUR SPA cont... SPA CABINET CARE Your spa comes standard with a PermaWood, or faux wood, cabinet. This cabinet requires no maintenance. You may wish to clean the cabi- net with mild soap and water from time to time. If you elected to pur- chase your spa with a wood cabinet, this cabinet is stained and sealed with an oil based acrylic stain.
  • Page 65: Cover Care

    are removed prior to filling the spa. This will help prevent sudsing and improper chemical balance. COVER CARE Cleaning of your spa cover is an important part of routine maintenance. Dirt acts as an abrasive to the vinyl topcoat, and can also cause wear to folds, seams and stitching.
  • Page 66: Chemical Treatment Of Water

    MAINTAINING YOUR SPA cont... CHEMICAL TREATMENT OF WATER Water from your tap is fine for showers, bathing and drinking. However, in a contained recirculating system such as in a spa, water must be treated with chemicals. The main purpose of chemical treatment is to keep the water sanitary and to maintain a specific balance of the water.
  • Page 67: Water Chemistry

    WATER CHEMISTRY CAUTION: The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous. Always follow these basic guidelines when handling the chemicals 1. Always read and follow the directions on the label, unless directed otherwise.
  • Page 68 WATER CHEMISTRY cont... WATER TREATMENT GLOSSARY cont... be rapid sanitizer loss, eye and skin irritation, The effects of low pH can expedited corrosion of metals, as well as staining throughout the spa. High pH can result in cloudy water, low sanitizer efficiency, as well as eye and skin irritation.
  • Page 69 9 - Organic Matter: These are carbon-derived substances typically generated by living organisms. In a spa, they are most frequently intro- duced into the water by bathers. Enzyme products such as Spa Perfect by Natural Chemistry are most effective at eliminating organic matter from your body of water.
  • Page 70 WATER CHEMISTRY cont... WATER TREATMENT GLOSSARY cont... 17 - Chloramines: Irritating, odorous forms of combined chlorine, formed by the reaction of chlorine with nitrogen containing waste prod- ucts. Chloramines are ineffective as a pool or spa sanitizer. High lev- els of chloramines can cause the problems of “Red Eyes” or “Stinging Eyes.”...
  • Page 71 and do not require electrical components. Most include some type of replaceable cartridge, that contains the copper, silver or zinc materials. 24 - Biguanide: The generic name for a non-chlorine, non-bromine, sanitizer that utilizes the polymer PHMB (polyhexamethylene bigu- anide). It is used to totally eliminate the use of chlorine or bromine. 25 - Biofilm: A slippery coating of microorganisms that can develop in poorly sanitized pools and spas.
  • Page 72: Spa Chemicals Glossary

    WATER CHEMISTRY cont... SPA CHEMICALS GLOSSARY 1 - Alkalinity Up: The total alkalinity of your spa water should be be- tween 80-140 PPM. A proper alkalinity will help buffer your spa water against sudden changes in pH. Every 2.5 tablespoons of Alkalinity Up will raise your alkalinity by 10 PPM in a spa holding 500 gallons of wa- ter.
  • Page 73 7 - pH Up: The effects of low pH can be rapid sanitizer loss, eye and skin irritation, expedited corrosion of metals, as well as staining through- out the spa. pH up can be purchased from your dealer in either liquid or solid granular form.
  • Page 74: Maintaining The Proper Ph

    WATER CHEMISTRY cont... MAINTAINING THE PROPER pH BALANCE The pH factor is a measure of the relative acidity or alkalinity in the water. It is measured on a scale of 1 to 14. Pure water has a value of 7, which is neutral.
  • Page 75: Warranty Information

    Artesian Spa Island Class Warranty This section is a description of your warranty. Here you will find descrip- tions of what is covered under your Island Class Spa warranty and what can void your warranty. PLEASE READ THE WARRANTY THOR- OUGHLY.
  • Page 76 T RANSFER OF OWNERSHIP. COMMERCIAL APPLICATIONS ARE EXCLUDED FROM THIS AND ALL WARRANTIES . The spa must be set on a level solid surface that is sufficient to support the entire length and width of the spa. Standard building practices must be followed. Dam- age caused by failure to have a leveled and supported foundation under the spa is not covered under warranty.
  • Page 77 WARRANTY cont... The stereo, speakers,stereo power supply, L.E.D. lighting, and Ozone are not included in this warranty but are covered under a separate war- ranty. Damage caused by weather, poor water chemistry, and/or im- proper maintenance will not be covered under this warranty. Alterations or replacements of components installed in the spa that are not pur- chased and/or approved by the MANUFACTURER, including incorrect wiring, will terminate the complete spa warranty.
  • Page 78 Stereo and Stereo Components The stereo and stereo components, including speakers, sub woofer, ste- reo power supply, wire harness and remote control are covered for 30 days from the date of delivery. Please note: Warranty coverage for both parts and labor is covered for 30 days only. Parts, not labor, will be cov- ered for one year from date of installation.
  • Page 79 WARRANTY cont... Limitations This warranty is void if this Artesian Spa has been subjected to altera- tion, misuse, or repairs have been performed by anyone other than an authorized agent of May Manufacturing LLC. Misuse or abuse is defined as: use of the spa in a nonresidential application, water temperature outside the range of 32 degrees F to 110 degrees F, damage caused by clogged or dirty filter cartridges, damage to the spa from an absence of a hard cover, damage to components from improper pH, use of any...
  • Page 80 Light Bulbs of Any Kind Removing a Spa from a Structure Pillows Filters Chemical Misuse/ Damage Filter Lids Any Part not Purchased from Artesian Spas Jet Inserts Valve Handles Pump Seals Draining and filling the Spa Acts of Nature Travel Charges...
  • Page 81: Interior Spa Diagram

    INTERIOR SPA DIAGRAM...
  • Page 82 1) Spa Pack 2) Heater 3) Therapy Pump...

This manual is also suitable for:

Grand caymanAntiguaCaptivaNevisBiminiSanta cruz

Table of Contents

Save PDF