OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Procedure
Step 1 Configure SDH services of the source NE (NE1).
1.
2.
Step 2 Configure SDH services on the sink NE (NE3). Refer to
Parameter
Level
Issue 02 (2011-06-30)
Select NE1 in the NE Explorer, and then choose Configuration > SDH Service
Configuration from the Function Tree.
Click Create on the lower-right pane to display the Create SDH Service dialog box. Set
the parameters that are required, and then click OK.
Parameter
Value in
This
Example
Level
VC12
Direction
Bidirectiona
l
Source Slot
3-SP3D
Source VC4
-
Source
1-5
Timeslot
Range(e.g.
1,3-6)
Sink Slot
1-SL1D-1
(SDH-1)
Sink VC4
VC4-1
Sink
1-5
Timeslot
Range(e.g.
1,3-6)
Activate
Yes
Immediately
Value in
This
Example
VC12
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description
In this example, E1 services are configured. Hence,
Level of the E1 services is set to VC12.
In this example, the services are transmitted and received
over the same path. That is, the services are
Bidirectional services.
In this example, the SP3D board in slot 3 of NE1 is
configured as the source tributary board. See
3-4.
-
In this example, five E1 services are configured between
NE1 and NE3. Hence, the service source occupies
VC-12s 1-5.
In this example, the SL1D board in slot 1 of NE1 is
configured as the sink line board. See
The timeslots where the service sink is located belong
to the first VC-4 (VC4-1).
In this example, five E1 services are configured between
NE1 and NE2. Hence, the service sink occupies VC-12s
1-5.
-
Step
Description
In this example, E1 services are configured. Hence, Level
of the E1 services is set to VC12.
3 Configuring SDH Services
Figure
Figure
3-4.
1. Set the parameters as follows.