OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Relationship with Other Parameters
The value range depends on the port rate.
Related Information
Maxpps: indicates the maximum number of frames per second.
Specifically,
l
l
l
l
According to the rule of Maxpps/10 < Error Frame Period Window(Frames) < Maxpps*60,
you know the value range of the Error Frame Period Window(Frames) parameter for a certain
port rate.
7.44 Error Frame Monitor Threshold(Frames)
Description
The Error Frame Monitor Threshold(Frames) parameter specifies the received N frames in
which the number of error frames reach the specified upper threshold. In this case, a link event
alarm is reported.
Impact on the System
After you set the Error Frame Period Window(Frames) and Error Frame Period Threshold
(Frames) parameters, a link event alarm is reported if the number of error frames received within
a certain period reaches the specified upper threshold.
Values
Valid Values
1-892800000, in step length of 1
Configuration Guidelines
None.
Relationship with Other Parameters
None.
Issue 02 (2011-06-30)
If the port rate is 10 Mbit/s, the Maxpps value is 14880.
If the port rate is 100 Mbit/s, the Maxpps value is 148800.
If the port rate is 1000 Mbit/s, the Maxpps value is 1488000.
If the port rate is 10 Gbit/s, the Maxpps value is 14880000.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Default Value
1
7 List of Parameters
Unit
Frame
7-41