OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Configuration Guidelines
Select the value according to the configuration.
Relationship with Other Parameters
If the S1 byte, the S2 byte, the S3 byte, the S4 byte, or an optical interface is set to transparently
transmit DCC overhead, the broadcast data port may fail to be set.
7.109 Working Mode (Broadcast Data Port)
Description
The Working Mode (Broadcast Data Port) parameter specifies the working mode of the local
interface at which broadcast data services are added or dropped.
Impact on the System
The system operation is not affected.
Values
Value
RS232
The following table lists the description of each value.
Value
RS232
Configuration Guidelines
None.
Relationship with Other Parameters
None.
Issue 02 (2011-06-30)
Valid Values
RS232
Description
Indicates an asynchronous transmission mode, in which no
handshake signal is available. An NE operating in RS232
mode can communicate with an NE operating in RS232 or
RS422 mode directly; in this case, data transmission is
transparent and the maximum rate is 19.2 kbit/s.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 List of Parameters
7-87