Problem
Display does not light
up
No sound or picture, but
the front panel power
light is ON.
No sound or picture
Bad picture/
Blocking Error
AV Out No picture
(Video)
The key is not working
For further information or any queries
please contact
Technical Support:
www.labgear.co.uk/support
14
S601a - Troubleshooting
Possible Causes
Power switch is not on or battery power
is low
AV IN cable connected, but no video
input
The satellite dish is not pointing at the
satellite.
No signal or weak signal
The satellite dish in not pointing at the
satellite
Signal is too strong
Satellite dish is too small
LNB noise factor is too high
The LNB is faulty
The system is connected by SCART
cable and TV is not in AV mode.
Battery power is low
Keys are blocked
Solution
Check to make sure meter power
switch is on
Connect to charger/mains adaptor
and make sure it is switched on
Check AV IN cable connection, check
AV source connection and signal
Adjust the dish. Check the Signal Level
in the Antenna Setup Menu
Check the cable connections. LNB and
other equipment connected between
the LNB and the meter and adjust the
dish.
Adjust the dish
Connect a signal attenuator to the
LNB input
Change to a larger dish
Change to an LNB with lower noise
factor
Change the LNB
Select rhe AV Input channel on the TV
Connect to charger/mains adaptor
Adjust the position of the meter in the
case or remove case