Daily Shut-Down
For experienced users
Once you have used the gun with a product and system,
and you have become comfortable with techniques on
how all the variables are affecting your operations and
maintenance requirements, Daily, Weekly, and Monthly
Maintenance requirements can be addressed specific
to your operation.
.
Turn the ball valves off, p/n PG-15-01, activate and
deactivate the gun 5 - 6 times to purge residual
pressure.
.
Drill out the chamber insert snout with correct size
drill bit for insert. (see chart in front of manual)
3.
Pull slide valve, p/n 16832-00 halfway back to limit
the air purge.
Air Switch
Maintenance
4.
Inject white lithium grease into zerk fitting until a
light mist of grease is purged through the snout.
Shut off the air purge.
Zerk Fitting
5.
Remove the air cap, p/n 23961-00 and set to side.
If solvent soaking is required, remove the o-ring,
p/n 23974-12 before soaking.
6.
Remove the insert, p/n 23977-XX and soak in
solvent until next usage.

Daily Start-Up

.
Clean the snout insert, p/n 23977-XX. Be sure both,
the face and bottom flat are Clean. Drill the snout bore
out with the correct size bit for Snout. (see chart in
front of manual)
.
Clean the inner bore of the chamber. Drill out the cham-
ber snout inlet bore as required.
3.
Install the snout insert.
4.
Install the air cap, p/n 23961-00 on to the chamber.
Tighten finger tight until the cap bottoms out. Snug down
with a ½ in. wrench. This does not require high torque.
Over tightening can result in chamber damage.