Mitsubishi Electric PLA-RP35EA Service Manual page 30

Mr.slim split-type, heat pump air conditioners
Hide thumbs Also See for PLA-RP35EA:
Table of Contents

Advertisement

9-7. TEST POINT DIAGRAM
Indoor controller board
PLA-RP35EA.UK
PLA-RP71EA.UK
TB5
Connect to wired remote controller
10.4-14.6 V DC
CN90
Connect to the wireless
remote controller board (CNB)
LED2
Power supply
(Wired remote controller)
CN44
Pipe temperature thermistor
– : Liquid (TH2)
– : Condenser/Evaporator (TH5)
CN20
Room temperature thermistor
(TH1)
CN4F
Drain float switch (FS)
CN105
IT
CN4G
Connect to the auto grille controller
board (CN4G)
– : 13 V DC ( : +)
– : communication line
– ,
0-5 V DC ( , : +)
CN4Z
i-see Sensor (Sensor)
CNP
Drain pump (DP)
– : 13 V DC
Vsp
Voltage between pins of C626
0 V DC (FAN stop)
1–6.5 V DC (FAN operation)
(Same as 6(+)–4(−) of CNMF)
CNMF
Fan motor (MF)
– : 310–340 V DC
– : 15 V DC
OCH626A
PLA-RP50EA.UK
PLA-RP100EA.UK
CN5Y
i-see Sensor motor (MT)
12 V pulse output
PLA-RP60EA.UK
PLA-RP125EA.UK
CNV
Vane motor (MV)
12 V pulse output
30
PLA-RP140EA.UK
SW1
Model selection
J41, J42
Jumper wire
(Pair No. setting with
wireless remote controller)
SW2
Capacity setting
LED3
Communication
(Indoor-outdoor)
SWE
Jumper switch
(Emergency operation)
CN32
Remote switch
CN51
Centrally control
– : Control signal
13 V DC pulse input ( : +)
– : Operation indicator
13 V DC ( : +)
– : Malfunction indicator
13 V DC ( : +)
CN41
HA terminal-A
CN2L
Lossnay
LED1
Power supply (I.B)
CN3C
Connect to the terminal block
(TB4)
(Indoor/outdoor connecting line)
0–24 V DC (Communication)
CN01
Connect to the terminal block
(TB4)
(Indoor/outdoor connecting line)
– : 220–240 V AC
F1
FUSE
(6.3A/250 V)

Hide quick links:

Advertisement

Table of Contents
loading