Unipower DPP1U-A1 Operating Manual

Dpp1u series. dc power distribution panels

Advertisement

Quick Links

P O W E R I N G
T E C H N O L O G Y
OPERATING MANUAL
DPP1U SERIES
DC POWER DISTRIBUTION PANELS
www.unipowerco.com
© 2017 UNIPOWER LLC
Manual No. DPP1U-5
All Rights Reserved
dpp1u-man-Rev5-0317.indd
UNIPOWER LLC • 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA • sales@unipowerco.com
North America: +1 954-346-2442 • Latin America: +1 954-905-1078 • Europe: +44 1903 768200

Advertisement

Table of Contents
loading

Summary of Contents for Unipower DPP1U-A1

  • Page 1 © 2017 UNIPOWER LLC Manual No. DPP1U-5 All Rights Reserved dpp1u-man-Rev5-0317.indd UNIPOWER LLC • 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA • sales@unipowerco.com North America: +1 954-346-2442 • Latin America: +1 954-905-1078 • Europe: +44 1903 768200...
  • Page 2: Table Of Contents

    DPP1U SERIES P O W E R I N G T E C H N O L O G Y OPERATING MANUAL Contents INTRODUCTION .......................4 FEATURES ..........................4 PRODUCT LINE .........................5 SAFETY & INDUSTRY STANDARDS ................5 WARRANTY (summary) ....................6 DESCRIPTION OF OPERATION ..................6 SPECIFICATIONS ......................7 FRONT PANEL DESCRIPTION ..................8 BACK PANEL DESCRIPTION ..................8...
  • Page 3 DPP1U SERIES P O W E R I N G T E C H N O L O G Y OPERATING MANUAL FIGURES Figure 1. DPP1U DC Power Distribution Panel ................4 Figure 2. Block Diagram ......................6 Figure 3. Front Panel View ......................8 Figure 4.
  • Page 4: Introduction

    DPP1U SERIES DC POWER DISTRIBUTION PANELS INTRODUCTION UNIPOWER’s DPP1U Series of circuit breaker panels provide distribution and overload protection for 1 to 16 circuits with circuit breakers that can be field installed/exchanged without the need for any additional tools. The panels are only one mounting position (1.75 inches) high.
  • Page 5: Product Line

    The following table lists the 8 available standard configurations of the DPP1U series. AMPS MODEL VOLTS INPUT MAX. # TOTAL EACH NUMBER EACH FEED FEEDS BREAKERS AMPS FEED DPP1U-A1 48/24 DPP1U-A6 DPP1U-A1-B1-S 48/24 DPP1U-A6-B6-S DPP1U-A1-B1 48/24 - 48/24 DPP1U-A6-B6 12 - 12 8 + 8 DPP1U-A1-B6 48/24 - 12 DPP1U-A6-B1...
  • Page 6: Warranty (Summary)

    God, negligence or the failure of customer to fully follow instructions with respect to installation, application or maintenance. For a complete text of UNIPOWER’s warranty conditions please request a copy from your local Sales Office.
  • Page 7: Specifications

    DPP1U SERIES P O W E R I N G T E C H N O L O G Y OPERATING MANUAL Alarm Circuits. The alarm circuits detect a tripped circuit breaker and, in this event, turn on the red part of the LEDs. The alarm circuits also each drive Form C relay contacts. If one or more circuits open or if there is an input power failure, the relays are de-energized and the contacts are used to control external audible or visual alarms.
  • Page 8: Front Panel Description

    DPP1U SERIES P O W E R I N G T E C H N O L O G Y OPERATING MANUAL FRONT PANEL DESCRIPTION The front panel of the DPP1U, shown in Figure 3 below, consists of the A and B sides and a center section.
  • Page 9: Figure 6. Output Barrier Strip Detail

    AWG wire sizes from no. 1 to 8 and one- or two- hole lugs. These lugs can be ordered directly from the manufacturer, Panduit Corp., using the model numbers shown in the table. A standard kit of four two-hole crimp type lugs for no. 6 AWG copper wire is available from UNIPOWER. Order kit no. 775-1434-0000. WIRE .25DIA.
  • Page 10: Unpacking And Inspection

    Also save the shipping carton and packing material as evidence of damage for the freight carrier’s inspection. UNIPOWER will cooperate fully in case of any shipping damage investigation. 10.3 Always save the packing materials for later use in shipping the unit. Never ship the rectifier 10.4...
  • Page 11: Installation

    See Sections 9.2 and 9.3. Output connections are made to the barrier terminal strips. See Section 9.4 and Figure 6. NOTE: Single feed models DPP1U-A1-B1-S and DPP1U-A6-B6-S have both left and right side input bus bars fitted. It is only necessary to connect the input feed to one side for correct operation.
  • Page 12: Installing Circuit Breakers

    DPP1U SERIES P O W E R I N G T E C H N O L O G Y OPERATING MANUAL 12.0 INSTALLING CIRCUIT BREAKERS The DPP1U Series employs pluggable circuit breakers that can be easily installed, removed or replaced without the need for an tools.
  • Page 13: Setup And Testing

    US +1 954 346 2442 UK +44 (0)1903 768200 This document is believed to be correct at time of publication and UNIPOWER LLC accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice.

Table of Contents