Danfoss VLT HVAC Drive FC 102 Operating Instructions Manual page 60

1.1-90 kw
Hide thumbs Also See for VLT HVAC Drive FC 102:
Table of Contents

Advertisement

Specifications
525-690 V
Enclosure
type
A3
B2/B4
B4/C2
C2/C3
C2
Table 8.14 525-690 V, Enclosure Types A, B and C
8
8
8.8.2 UL Compliance
3x200-240 V
Power
[kW]
1.1
1.5
2.2
3.0
3.7
5.5-7.5
11
15
18.5-22
30
37
45
Table 8.15 3x200-240 V, Enclosure Types A, B and C
58
Power [kW]
Recommended
fuse size
1.1
gG-6
1.5
gG-6
2.2
gG-6
3
gG-10
4
gG-10
5.5
gG-16
7.5
gG-16
11
gG-25 (11)
15
gG-32 (15)
18
gG-32 (18)
22
gG-40 (22)
30
gG-63 (30)
37
gG-63 (37)
45
gG-80 (45)
55
gG-100 (55)
75
gG-125 (75)
Bussmann
Bussmann
1)
Type J
Type RK1
KTN-R-10
JKS-10
KTN-R-15
JKS-15
KTN-R-20
JKS-20
KTN-R-25
JKS-25
KTN-R-30
JKS-30
KTN-R-50
JKS-50
KTN-R-60
JKS-60
KTN-R-80
JKS-80
KTN-R-125
JKS-125
KTN-R-150
JKS-150
KTN-R-200
JKS-200
KTN-R-250
JKS-250
Danfoss A/S © Rev. 06/2014 All rights reserved.
Operating Instructions
Recommended
max. fuse size
gG-25
gG-25
gG-25
gG-25
gG-25
gG-25
gG-25
gG-63
gG-80 (30)
gG-100 (37)
gG-125 (45)
gG-160 (55-75)
Recommended max. fuse
Bussmann
Bussmann
Type T
Type CC
JJN-10
FNQ-R-10
JJN-15
FNQ-R-15
JJN-20
FNQ-R-20
JJN-25
FNQ-R-25
JJN-30
FNQ-R-30
JJN-50
JJN-60
JJN-80
JJN-125
JJN-150
JJN-200
JJN-250
Recommended circuit
breaker (Moeller)
PKZM0-16
-
-
-
Bussmann
Type CC
KTK-R-10
KTK-R-15
KTK-R-20
KTK-R-25
KTK-R-30
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Max. trip level [A]
16
-
-
-
Bussmann
Type CC
LP-CC-10
LP-CC-15
LP-CC-20
LP-CC-25
LP-CC-30
-
-
-
-
-
-
-
MG11AK02

Advertisement

Table of Contents
loading

Table of Contents