Compatibility Between Protection Releases And Cb; Abbreviations And Notes; Abbrevations; Safety Notes - ABB Tmax T7 Operating Instructions Manual

T7-t8-x1 low voltage air circuit breakers protection releases
Hide thumbs Also See for Tmax T7:
Table of Contents

Advertisement

1.1. Compatibility between protection releases and CB

This table summarizes all the possible combinations between the different protection releases and Emax X1 and Tmax T7-T8
circuit-breakers.
CB / Release
T7
T8
X1
Note:
(1): LSIG version available
(2): PR332/P MM available with SACE Tmax T7 and T8 CB

1.2. Abbreviations and notes

1.2.1.

Abbrevations

Abbreviations
YO
YC
CB
CS
Ekip Connect
Emax
Tmax T7-T8
HW
In
i-Test
MT
Pn
Pn
fase
Protection release
RMS
SdZ
SW
TC
Rc
Trip
TV
Un
SGR
Vaux

1.3. Safety Notes

Read this manual carefully and completely: use of the protection releases should be reserved to qualified and expert personnel only.
WARNING: this symbol highlights information about operations, actions or circumstances that can cause injuries
to the personnel, damage to the protection release or economic losses.
You must assume that safe usage is impossible if:
1. The protection release shows visible signs of damage.
2. The protection release does not function (e.g. with autotest or by means of the trip test unit).
3. The release has been damaged during transport.
The protection release must be put out of service to prevent accidental use.
WARNING: Prior to servicing and/or replacing, the circuit-breaker must be open.
Also remember to disconnect all power supplies connected.
1.3.1.

Notes for dielectric stiffness tests

WARNING:
Dielectric strength tests must not be performed on the inputs and outputs of PR332/P and PR333/P.
B0431
Model
PR331
PR332
X
X
(1)
(2)
X
X
(1)
(2)
X
X
Meaning
Opening coil
Closing coil
Circuit-Breaker
Current Sensor
Communication software for PC, for electronic devices installed in ABB SACE CB
Series of ABB SACE air circuit-breakers
Series of ABB SACE molded-case circuit-breakers
Hardware
Rated current of the Rating Plug installed in the circuit-breaker
"Info/test" button on protection release
Thermal memory
Circuit-breaker rated power
Phase rated power
Electronic protection and operating unit for ABB SACE circuit-breakers
Root mean square value
Zone selectivity
Software
Trip Coil (opening solenoid)
Current sensor for residual current reading
CB opening action generated by protection release
Voltage transformer
Rated voltage of the voltage transformers installed (phase voltage)
External current sensor for earth fault current reading
Auxiliary power supply
B1751
PR333
X
Apparatus
Emax X1-Tmax T7-Tmax T8
Doc. no.
1SDH000587R0002
Scale
Page No
6/66