Start Up; Operation - Kärcher HD 10/25-4 S Manual

Hide thumbs Also See for HD 10/25-4 S:
Table of Contents

Advertisement

Available languages

Available languages

 Insert the high pressure nozzle onto the
spray lance.
 Install union nut and hand-tighten it
(EASY!Lock).
 Join the spray lance with the trigger gun
and tighten until hand-tight
(EASY!Lock).
 Join the high-pressure hose with trigger
gun and high-pressure connection of
the appliance and tighten until hand-
tight (EASY!Lock).
 Lock a cable clip in the side-hole on the
handle.

Start up

WARNING
Risk of injury! Appliance, accessories, sup-
ply lines and connections must be in fault-
free condition. If they are not in a perfect
state then the appliance must not be used.
Electrical connection
DANGER
Danger of injury by electric shock.
– It is imperative to connect the appliance
to the electric mains by means of a plug.
It is forbidden to permanently connect
the appliance to the power supply. The
plug serves for the disconnection from
the mains.
– The appliance may only be connected
to alternating current.
– Minimum fuse strength of the socket
(see Technical Data).
– The highest allowed net impedance at
the electrical connection point (refer to
technical data) is not to be exceeded. In
case of confusion regarding the power
impedance present on your connection,
please contact your utilities provider.
– Use the extension cord that has an ad-
equate cross-section (see "Technical
Data") and unwind it fully from the cable
drum.
For connection values, see type plate/tech-
nical data.
 Unwind the mains cable and place it on
the floor.
 Insert the mains plug into a socket.
Water connection
Connection to the water supply
WARNING
Observe regulations of water supplier.
According to applicable regula-
tions, the appliance must never be
used on the drinking water net
without a system separator. A suit-
able system separator by KÄRCHER or al-
ternatively a system separator according to
EN 12729 type BA must be used.
Water that was flowing through a system
separator is considered non-drinkable.
For connection values refer to technical
specifications.
 Connect the supply hose (minimum
length 7.5 m, minimum diameter 1") to
the water connection point of the appli-
ance (such as the tap).
Note:
The supply hose is not included.
 Open the water supply.
Drawing in water from open reservoirs
 Screw the suction hose with filter (order
no. 4.440-238.0) to the water connection.
 Deaerate the appliance:
Unscrew the nozzle.
Switch on the appliance and let it run
until the water exiting is bubble-free.
 Switch off the appliance and fit the noz-
zle again.
DANGER
Risk of injury! Never use the appliance
without the spray lance attached. Check
and ensure proper fitting of the spray lance
prior to each use. The screw connection of
the spray lance must be finger-tight.
Risk of explosion!
Do not spray flammable liquids.
If the appliance is used in hazardous areas
(e.g. filling stations) the corresponding
safety regulations must be observed.
Risk of injury! Hold the hand spray gun and
the spray pipe firmly with both hands.
– 5
EN

Operation

7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents