4000 Series
Art. 4800 - 4800M

TECHNICAL SPECIFICATION

Power Supply:
Power Consumption:
Working Temperature:

PrOGrAMMING FLOW-CHArT

Red LED will be ON
Melody
Melody
Melody
Melody
Melody
Melody
Melody
Red LED will be OFF
Art. 4800 - 4800M - Installation instructions
Digital codelock module
12/24 Vac/dc – 2VA
Stand-by:
20mA
Operating:
70mA
-10 +50° C
ENTER "ENGINEEr'S CODE"
AND PRESS "ENTEr"
CONFIRM OR CHANGE "ENGINEEr'S CODE"
AND PRESS "ENTEr"
ENTER "ACCESS 1 CODE"
AND PRESS "ENTEr"
ENTER "ACCESS 1 TIME"
AND PRESS "ENTEr"
ENTER "ACCESS 2 CODE"
AND PRESS "ENTEr"
ENTER "ACCESS 2 TIME"
AND PRESS "ENTEr"
ENTER "ACCESS 3 CODE"
AND PRESS "ENTEr"
ENTER "ACCESS 3 TIME"
AND PRESS "ENTEr"
SYSTEM rEADY TO USE
First time 6 times 1 "111111"
factory preset
Type again six times "1"
or the new enginner's code 4 to 8 digits
Code to enable
relay 1
4 to 8 digits
2 digits (01 to 99)
I.E. 05 = 5 seconds
00 = remain open time
Code to enable
relay 2
4 to 8 digits
2 digits (01 to 99)
I.E. 05 = 5 seconds
00 = remain open time
Code to enable
relay 3
4 to 8 digits
2 digits (01 to 99)
I.E. 05 = 5 seconds
00 = remain open time