08. Troubleshooting

Error
POWER LED does not light
POWER LED flashes quickly
POWER LED flashes slowly
DANTE LED does not light up
(see Power LED)
DANTE LED is flashing
MADI coaxial LED lights low
ADAT Input LED flashes
ADAT Input LED is lit constantly,
regularly interrupted by flick-
ering
10
Possible cause
Power supply not plugged in or
defective
The device is switched off
Power button pressed
The Verto unit is booting in the
start-up process
Mains cable defective or the
wrong type (crossed) is used
Verto is booting
Error in the DANTE network
No connection to the Dante
network
Device is „slave", but no "Mas-
ter" was found on the DANTE
network.
Sample rate on the network
has been changed
Both ports (opto & coax) re-
ceive valid signal
This is a status indication, not
an error.
A sync process has failed
Both devices are „Master".
Troubleshooting
Check the power supply
Switch on the device with the
power button. Seriously.
The power LED flashes quick-
ly when the power button is
pressed on a switched-on de-
vice.
Wait approx. 20 seconds for the
boot-up-sequence to finish.
Use a different network cable
Wait approximately 20s until the
boot process is finished
Check the functioning of the
DANTE network.
Check the functioning of the
DANTE network.
Set a device in the DANTE net-
work to „Master"
When changing the sample rate,
the outputs are muted briefly.
Both signals are valid, but the
optical port is automatically used
for DANTE.
Set all connected ADAT devices
to „Slave".
Set all connected ADAT devices
to „Slave".