G. Appliance Break-In
Initial Break-in Procedure
• The fireplace should be run three to four hours
continuously.
• Turn the fireplace off and allow it to completely cool.
This cures the materials used to manufacture the fire-
place.
NOTICE! Open windows for air circulation during fire-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
H. Operation During A Power Outage (IPI)
THE LEGACY42-IFT, being a power vented appliance,
will NOT function during a power outage.
I. Valve and Component Access
Gas valve and electrical components are located within
the appliance valve compartment, beneath the burner
and hearth refractory. The center hearth refractory must
be removed to access components. See Figure 3.5.
Center Hearth Refractory
Figure3.5
To remove the center hearth refractory, lift the rear
edge of the refractory and tilt towards the front of the
appliance. It may be necessary to lift silghtly on grate
in order for hearth refractory to clear.
Carefully lift center hearth refractory out of the appli-
ance and set aside.
Gas valve and electrical components should now be
accessible. See Figure 3.6.
12
Heatilator • Legacy42-IFT Owner's Manual • 4095-900 Rev. A • 9/17
Blower Speed Control
Figure 3.6
Control Module
Gas Valve