J. Intellifire™ Touch
Operating Instructions
The LEGACY42-IFT product comes factory equipped
with the IFT-RC400 remote.
1. The Electronic Control Module has a three-position
ON/OFF/REMOTE selector switch that must be set
for proper operation. See Figure 3.8. When changing
switch positions, it is important to pause in each position
for 1-2 seconds.
OFF Position:
The appliance is off and will not respond to any command
from the remote control. The appliance should be in
the OFF position during installation, setup, service and
fuel conversion.
ON Position:
Disabled in power vent mode, will result in a power vent
fault code.
Remote Position:
The remote position allows operation of the appliance
from the remote control. The control module switch
must be in this position to pair with the remote control
and the auxiliary module. See the remote control
installation manual for detailed instructions on pairing.
Note: The control module has a safety feature that will
automatically shut down the appliance after 9 hours
of continuous operation without receiving a command
from the remote.
2. A wired wall switch is NOT available when a power vent
is used, such as with the LEGACY42-IFT product.
3. A control module reset is required if the module is in a
lockout mode. When this occurs, the appliance is shut
down and the control module status indicator LED will
be blinking a RED/GREEN error code along with a one-
time audible double beep. Refer to the troubleshooting
chart to interpret the error code and take corrective
action as required.
CAUTION! Risk of burns! Appliance surfaces are hot
when operating and during cool down. Use care and
wear gloves when opening the front and accessing
components inside the appliance.
Heatilator • Legacy42-IFT Owner's Manual • 4095-900 Rev. A • 9/17
Appliance ON/OFF
The IFT-RC400 remote is used to control the ON/OFF
function of the appliance. Follow instructions included
with the remote.
DANGER
RISK OF EXPLOSION
DO NOT cycle the ON/OFF/REM selector
switch more than one time within a five minute
period. Gas may accumulate in firebox. Call a
qualified service technician.
Remote Control
3-Position Switch
RF Module
Status Indicator LED
Figure 3.8
AC Module
Control Module