Download Print this page

Foma D902iS Manual page 31

Hide thumbs Also See for D902iS:

Advertisement

Disconnection reason list
■ Packet communication
Value
27
APN is not present or is incorrect.
30
Disconnected by network.
33
Terminal does not subscribe to packet
communication.
36
Normal disconnection.
■ 64K data communication
Value
1
Specified number does not exist.
16
Normal disconnection.
17
Communication is impossible because remote
device is busy.
18
You made a call but did not receive a response
within the specified time.
19
A call was made to the other party, but no
response.
21
The remote device rejected incoming calls.
63
The service and option of the network are not valid.
65
Unavailable processing speed was specified.
88
You made a call to a terminal or received a call
from a terminal with different terminal properties.
Error messages list
No.
Text display
10
SIM not
No UIM (FOMA card) is set.
inserted
15
SIM
Other than UIM (IC card equivalent
wrong
to UIM) is inserted.
16
incorrect
Incorrect password
password
100
unknown
Unknown error
Supplement to AT command
■ Command name: AT + CGDCONT = [parameter]
Sets the dialup connection (APN) for packet
communication.
Format
AT + CGDCONT = [<cid>[, "PPP" [, "<APN>"]]]
Parameter description
<cid>: 1 to 10
"mopera.ne.jp" (APN) is registered in cid 1, and
"mopera.net" in cid 3.
<APN>: Optional
Example of execution
The command used to register an APN named
"abc" (when <cid> = 2).
AT + CGDCONT = 2, "PPP", "abc"
Reason
Reason
Reason
Operation performed when parameter is omitted
AT + CGDCONT =
Clears all <cid> settings. However, entry for
"<cid> = 1" and "<cid> = 3" is restored to the
default setting.
AT + CGDCONT = <cid>
Clears the specified <cid> settings. However,
entry for "<cid>=1" and "<cid> = 3" is restored to
the default setting.
AT + CGDCONT = ?
Displays a list of assignable values.
AT + CGDCONT?
Displays the current setting values.
■ Command name: AT + CGEQMIN = [parameter]
Registers the criteria for judging whether to
approve QoS provisioned by the network when
PPP packet communication is established.
Format
AT + CGEQMIN = [<cid>[,,<Maximum bitrate
UL>[,<Maximum bitrate DL>]]]
Parameter description
<cid>:1 to 10
"mopera.ne.jp" (APN) is registered in cid 1 and
"mopera.net" in cid 3.
<Maximum bitrate UL>: None or 64
<Maximum bitrate DL>: None or 384
For "Maximum bitrate UL" and "Maximum bitrate
DL", the minimum communication speed (in
kbps) is set for both upload and download traffic
between FOMA terminal and the base station. If
the parameter is set to "None (default)", all
speeds are permissible. However, if "64" and
"384" are set, any connection at a speed less
than the above limit is not permitted, and
chances are that packet communication will not
be connected.
Example of execution
(1) Command used to permit all speeds both
upload and download (when <cid> = 2)
AT + CGEQMIN = 2
(2) Command used to permit only 64kbps upload
and 384 kbps download (when <cid> = 4)
AT + CGEQMIN = 4,,64,384
(3) Command used to permit 64 kbps upload and
all speeds download (when <cid> = 5)
AT + CGEQMIN = 5,,64
(4) Command used to permit all speeds upload
and only 384 kbps download (when <cid> = 6)
AT + CGEQMIN = 6,,,384
30