7 DEVICE PARAMETERS

The operating parameters set on the device itself can be viewed by printing the parameters (see point PRINTING THE DEVICE
PARAMETERS in the user manual), or in a file downloaded by TraceLog (see the SERVICE PARAMETERS section of the TraceLog
manual).
The examples shown refer to the WD2145 device.
7.1

Printout

* Parameters used for display of the time remaining
Fw version installed
Total cycles performed
Cycles since last service
Dryer operating hours (not featured on model considered)
File overwriting; 1=yes, 0=no
Printout language
Water type enabling; 1=yes, 0=no
Dispenser pumps fitted; 1=yes, 0=no
Flow switches fitted; 1=yes, 0=no and relative % ratio (see flow switch setting
section of TraceLog manual)
Dispenser pump delivery rate
(ml/min)
Quantity of product dispensed (ml/litre) by program
Absolute filter and dryer fitted: 1=yes, 0=no
Aqua stop accessory fitted: 1=yes, 0=no
Door opening at end of cycle; 1=on, 0=off
Power supply*: 1=three-fase, 0=single-phase
Mains frequency: 50=50Hz, 60=60Hz, AUTO=automatic detection mode
Extra fill time (min.)
Sump washing before demi rinse: 0=NO, 1=YES
Condenser activation: 0=NO, 65=YES, from 65°C upward
Water hardness and relative litres treatable by softener
Powder dispenser: 1=installable, 0= NOT installable
Last rinse signalling: 0=NO, 1=YES
Cycle repetition: 0=NO, 1=YES and number of
Detergent dispensing modification lock 0=NO,
1=YES