Vector 4000 Shoe Shimming
9.4
SHOE SHIMMING TABLE
Pressure bar (psi)
∆P ≤ 5 (72.5)
5 (72.5) ≤ ∆P ≤ 7.5 (108.75)
7.5 (108.75) ≤ ∆P ≤ 10 (145)
10 (145) ≤ ∆P ≤ 15 (217.5)
9.5
GENERATED NOISE AND TEMPERATURE
NOISE
The Wanner Pumps do not generate more than 60dB during their operation.
TEMPERATURE
The cover and the pump casing can become very hot due to the friction on the hose and liquid temperature. If
you need to limit the pump temperature, please contact your Wanner distributor.
1204 Chestnut Avenue, Minneapolis, MN
T e l : ( 6 1 2 ) 3 3 2 - 5 6 8 1
F a x : ( 6 1 2 ) 3 3 2 - 6 9 3 7
Toll-free fax [US only]: (800) 332-6812
www.vectorpump.com
email: sales@wannereng.com
36
PUMP TYPE 4010
Speed - Rpm
0 to 30
30 to 100
0 to 30
30 to 65
0 to 30
30 to 50
0 to 30
30 to 42
55403
Number of
Pressure bar (psi)
shims
0
∆P ≤ 5 (72.5)
0
2
5 (72.5) ≤ ∆P ≤ 7.5 (108.75)
1
3
7.5 (108.75) ≤ ∆P ≤ 10 (145)
2
4
10 (145) ≤ ∆P ≤ 15 (217.5)
3
© 2016 Wanner Engineering, Inc. Printed in USA
VEC-991-4000B 12/2016, Revised 5/2017
PUMP TYPE
4014
Speed - Rpm
0 to 20
20 to 60
0 to 20
20 to 47
0 to 20
20 to 37
0 to 20
20 to 31
Number of
shims
0
0
2
1
3
2
4
3