Vector 4000 Maintenance
6.3.3 REASSEMBLY OF THE HOSE (Cont'd)
3. Insert hose at the outlet port. See Figure 8.
WARNING!
Use care when you jog/run the motor to avoid injury.
4. Reverse the direction of rotation of the motor.
5. While pushing on the hose, jog/run the motor and check the
direction of rotation.
6. The shoes mounted on the wheel are going to "swallow" the
hose and push it out of the inlet port. Jog the motor to bring
the hose against the flange (47). See Figure 9.
7. Assemble the clamps (8) and (9) on the inlet side. Mount
the insert (12) into the hose. Tighten clamps.
FOR MODELS 4003, 4004
Dismantle the bracket 18. Mount clamps on the hose. Mount
the insert into the hose. Fix bracket (18) and block the insert
with circlips (24). Tighten clamps.
Note: If you have difficulty assembling inserts into the
pump hose, coat them slightly with Wanner lubricant.
Never use another lubricant.
8. Assemble the brackets (18) and pre-assemble flange (47) on
the outlet side with two temporary bolts.
FOR MODELS 4003, 4004
Assemble the brackets at the outlet side.
9. Reverse the direction of rotation of the motor.
WARNING!
Use care when you jog/run the motor to avoid injury.
10. Jog/run the motor to bring the hose against the discharge
flange.
11. Perform step 7 at discharge side.
12. Fill the pump with the necessary quantity of Wanner
lubricant. See 6.1. and 9.3.
13. Take away the temporary flange bolts and fix the piping on
both suction and discharge sides.
14. Open the valves at the suction and discharge sides.
15. Check the direction of rotation of the pump. Check for any
possible lubricant leakage by the inserts, sleeves or cover.
16
Wanner Engineering, Inc.
Outlet Port
Figure 8
18
Figure 9
United States
Instant Information:
(612) 332-5681
Fax (612) 332-6937
47
www.vectorpump.com
VEC-991-4000B