Vector 4000 Maintenance

6.6 ADDITIONAL INFORMATION

Note: The numbers in parentheses are Reference Numbers located in the Parts List exploded views of this manual.
6.6.1 MAINTENANCE AND PERIODIC INSPECTIONS TABLE (4003, 4004, 4006, 4007, 4010, and 4014).
1
Pump hose replacement
2
Lubricant replacement.
3
Gearbox oil replacement.
4
Replacement of the seal ring (27).
5
Replacement of the shaft seal (26).
6
Replacement of the shaft seal (105)
and (106)
7
Replacement of the shoes.
8
Replacement of the cover seal (10).
8
Replacement of the sleeves (6).
9
Replacement of the bearings (103)
and (104)
9
Check the lubricant level.
10
Check for lubricant leakage at the
leakage channel.
11
Check the
pump casing to
cern possible leakages around the
cover, the sight glass, the flanges and
the sleeves.
12
Check for wear on the shoe's pressing
surface.
13
Check the presence of a gearbox oil
leakage.
14
Check for strange noises coming
from the pump, gearbox and bear-
ing case or abnormal pump casing
temperature.
22
Wanner Engineering, Inc.
In prevention, change the pump hose
after 90 % of the life time of the first
hose.
At the end of two hose changes or 5000
hours of use. Otherwise, in every hose
break
Refer to the gearbox maintenance
manual provided with the pump.
In case of presence of lubricant in the
leak channel.
In case of presence of lubricant in the
leak channel.
In case of presence of oil in the leak
channel or at the lip seals.
If these are worn on the contact
surface.
In the case of a leak around the pump
cover.
If damaged.
If there are abnormal noises coming
from the bearing case.
Before starting the pump and
periodically during the pump service.
Before starting the pump and periodi-
cally during the pump service.
dis-
Before starting the pump and periodi-
cally during the pump service.
At every hose change.
Before starting the pump and periodi-
cally during the pump service.
Periodically during the pump service.
United States
(612) 332-5681
See 6.3.
See 6.1. and 9.3.
See 6.4.2.
See 6.4.2.
See 6.4.2. and 6.6.
See 6.4.1.
See 6.3.2.
Refer to 6.3. Perform steps
1 thru 4 of 6.3.1 and change
sleeves. Use care.
See 6.4. and 6.6.
See
6.1.
See 6.4.
See 6.4.
See 3.5.