Vector 4000 Maintenance
6.3.1 HOSE REMOVAL (Cont'd)
4. -At the discharge outlet, loosen clamps (8) and (9).
-Remove the insert (12) and remove the flange (47) as
well as the brackets (18). See Figure 3.
5. Remove clamps.
8
9
18
12
Figure 3
WARNING!
The hose can come out of the pump casing very fast and
cause harm. Ensure that no one is in front of the pump´s
outlets when removing the hose.
WARNING!
Use care when you jog/run the motor to avoid injury.
6. Carefully jog/run motor to expel hose from pump casing
outlet side. See Figure 4.
Pump casing
Figure 4
14
Wanner Engineering, Inc.
FOR MODELS 4003, 4004:
At the pump outlet, loosen clamps (8) and (9).Remove circlips (24)
and dismantle bracket (18). Remove insert (12) and clamps.
See Figure 5.
47
United States
(612) 332-5681
9
8
18
Figure 5
Instant Information:

www.vectorpump.com

Fax (612) 332-6937
VEC-991-4000B
12
24