Vector 4000 Maintenance

6.2 HOSE CLEANING

The hose can be cleaned without removing. Use water or
cleaning liquid (check compatibility with hose material). With
Some pumped material requires cleaning after each use to
avoid material hardening in the hose.
CAUTION: Make sure that the cleaning liquid temperature
is the same as the hose material.

6.3 HOSE REPLACEMENT

Note: The numbers in parentheses are Reference Numbers
located in the Parts List exploded views of this manual.
CAUTION: Before any hose change, check the following
points:
1. Skilled personnel are to perform this service and have read
and understand this manual.
2. Close inlet and outlet valves to minimize material loss.
3. Wear clothes that provide protection when using the
pumped material.
4. Observe all safety and environmental rules governing the
use of the pumped material.
6.3.1 HOSE REMOVAL
1. Disconnect and remove suction and discharge piping.
2. Drain lubricant as outlined in Section 6.1.
3. Loosen clamps (8) and (9) at the suction inlet.
Remove insert (12) and flange (47) See Figure 1.
8
Wanner Engineering, Inc.
9
47
12
Figure 1
FOR MODELS 4003, 4004:
3. Loosen clamps (8) and (9) at suction inlet. Remove
circlips (24) and remove bracket (18) and insert (12). See
Figure 2.
8
18
United States
Instant Information:
(612) 332-5681
Fax (612) 332-6937
9
12
Figure 2
www.vectorpump.com
VEC-991-4000B
24
13