Type B (Conventional Flue With Fan Assistance) - Lochinvar ECOKNIGHT EKW46CE Installation Manual

Floor standing gas fired condensing circulating type water heater
Table of Contents

Advertisement

10.17
TYPE B
(CONVENTIONAL FLUE WITH FAN ASSISTANCE)
23
When the water heater is installed as a Type B
manufacturer's specific instructions.
COMPONENTS INCLUDED
Item No.
M75256
AIR INLET TRANSITION Ø80mm ALU
M73039
AIR INLET GRILLE Ø80mm ALU
M85279
SAMPLING POINT Ø80mm PP
COMPONENTS INCLUDED
Item No.
M75257
AIR INLET TRANSITION Ø100mm ALU
M86787
APPLIANCE AIR INLET GUARD Ø100mm
M85189
SAMPLING POINT Ø100mm PP
The above is a kit of components to facilitate conventional flueing of the appliance and must be fitted prior to fitting any other flue
components.
10.17.1
TYPICAL CONVENTIONAL FLUE ARRANGEMENT
appliance, the flue system should be installed in accordance with the flue
23
FAN ASSISTED OPEN FLUE STARTER ASSEMBLY
Kit contains components to start the connection to the appliance only
MODELS EKW46CE,EKW61CE
Description
FAN ASSISTED OPEN FLUE STARTER ASSEMBLY
Kit contains components to start the connection to the appliance only
Description
1.Insert the exhaust transition into the exhaust port of the water heater.
2..Insert the flue temperature sensor into the location hole on the exhaust transition.
If the flue temperature sensor is not fitted, the flue gas may exceed the
maximum temperature rating of the flue and can lead to severe personal
injury, death or substantial property damage.
3.Insert the air intake into the intake connection and tighten the worm drive clip.
4.Insert the air inlet grill into the air inlet transition. For safety reasons this must be fitted prior
to operating the appliance.
Item No EKWCF001
Item No EKWCF002
MODELS EKW86CE
Number
Quantity
1
1
2
1
3
1
Number
Quantity
1
1
2
1
3
1
36