Technical Data - Lochinvar ECOKNIGHT EKW46CE Installation Manual

Floor standing gas fired condensing circulating type water heater
Table of Contents

Advertisement

4.0

TECHNICAL DATA

Model Number
GENERAL DATA
Product I.D. Number
Classification
Input (gross)
Input (net)
Recovery Rate (44° ΔT)
Recovery Rate (50° ΔT)
Heat generator seasonal efficiency
Shipping Weight
NO
@0%O
2
X
GAS DATA – G20
Nominal gas inlet pressure
Maximum gas inlet pressure
Minimum gas inlet pressure
Gas flow rate
Flue gas mass rate (@ 9.0% CO2)
Gas inlet connection size
GAS DATA – G31
Nominal gas inlet pressure
Maximum gas inlet pressure
Minimum gas inlet pressure
Gas flow rate – m
/hr
3
Flue gas mass rate (@ 10.5% CO2)
Gas inlet connection size
ELECTRICAL DATA
Power consumption
Power supply
Protection class
WATER DATA
Water content
Water connections (F & R)
Max. water pressure (PMS)
Min. water pressure
Maximum water temperature
EKW46CE
kW
44
kW
39.6
l/hr
806
l/hr
709
%
96.4
kg
75
mg/kWh
39
mbar
mbar
mbar
m3/hr
4.2
g/sec
16
" BSP
½
mbar
mbar
mbar
m3/hr
1.7
g/sec
16.7
" BSP
½
W
120
litres
4.9
" BSP
bar
bar
°C
EKW61CE
EKW86CE
CE 0063CQ3351
II
2H3B/P
61.5
55.4
1153
1014
95.6
79
39
20
25
17.5
5.9
22.3
½
37
45
27
2.3
23.2
½
144
Single phase 230v/50Hz
IP00
6.4
1 ¼
11
0.5
80
83.5
75.2
1567
1379
95.6
102
39
8
30.4
¾
3.1
31.6
¾
180
9.1
2
9

Hide quick links: