Allnet ALL-SG8910PM User Manual

Allnet ALL-SG8910PM User Manual

8-port 10/100/1000m poe+ with 2 gigabit sfp/rj45 combo ports layer 2+ fanless full managed poe switch
Table of Contents

Advertisement

Quick Links

8-Port 10/100/1000M PoE+ with 2
Gigabit SFP/RJ45 Combo Ports Layer
2+ Fanless Full Managed PoE Switch
ALL-SG8910PM
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALL-SG8910PM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Allnet ALL-SG8910PM

  • Page 1 8-Port 10/100/1000M PoE+ with 2 Gigabit SFP/RJ45 Combo Ports Layer 2+ Fanless Full Managed PoE Switch ALL-SG8910PM USER MANUAL...
  • Page 2 This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Default-IP 192.168.2.1 Password: admin © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 3: Table Of Contents

    3.1.5. Configuration - Security ..................52 3.1.5.1. Security - Switch - Users................52 3.1.5.2. Security - Switch - Privilege Level ...............54 3.1.5.3. Security - Switch - Authentication Method ..........56 © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 4 3.1.5.3.2. Security - AAA - TACACS+ ..............121 3.1.6. Configuration - Aggregation ................123 3.1.6.1. Aggregation - Static ..................123 3.1.6.2. Aggregation - LACP ..................125 3.1.7. Configuration - Loop Protection ..............127 © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 5 3.1.17.3. VCL - IP Subnet-based VLAN ..............188 3.1.18. Configuration - Voice VLAN ................190 3.1.18.1. Voice VLAN - Configuration ..............190 3.1.18.2. Voice VLAN - OUI ..................192 © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 6 3.2.5. Monitor - DHCP ....................242 3.2.5.1. DHCP - Server ....................242 3.2.5.1.1. DHCP - Server - Statistics ..............242 3.2.5.1.2. DHCP - Server - Binding ................ 244 © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 7 3.2.10.2. MVR - MVR Channel Groups ..............293 3.2.10.3. MVR - MVR SFM Information ..............295 3.2.11. Monitor - IPMC ....................297 3.2.11.1. IPMC - IGMP Snooping ................297 © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 8 3.4.4.1. Configuration - Save Startup-config ............342 3.4.4.2. Configuration - Download ................. 343 3.4.4.3. Configuration - Upload ................344 3.4.4.4. Configuration - Activate ................345 3.4.4.5. Configuration - Delete ................346 © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 9 Table of Contents Appendix A: Product Safety – CE – GPL ................347 © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 10: Before Starting

    Before Starting In Before Starting: This section contains introductory information, which includes: Intended Readers Icons for Note, Caution, and Warning Product Package Contents © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 11: Intended Readers

    A Caution icon indicates either a potential for hardware damage or data loss, including information that will guide you to avoid these situations. A Warning icon indicates potentials for property damage and personal injury. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 12: Product Package Contents

    One pair Rack-mount kit + 8 Screws Note: If any item listed in this table above is missing or damaged, please contact your distributor or retailer as soon as possible. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 13: Chapter 1: Product Overview

    In Product Overview: This section will give you an overview of this product, including its feature functions and hardware/software specifications. Product Brief Description Product Specification Hardware Description Hardware Installation © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 14: Product Brief Description

    VLAN and Spanning Tree, LACP, LLDP; sFlow, port mirroring, cable diagnostic and advanced Network Security features. It also provides Console CLI for out of band management and SNMP, Web GUI for in band Management. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 15 You can set the frequency of detecting, number of times of detecting, and the time period to perform power cycle when there’s no reply via the switch’s PoE configuration web page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 16: Product Specification

    IPv6 MLD Snooping Supports 1024 MLD groups MLD Static Multicast Addresses Supports 1024 static multicast addresses Querier, Immediate Leave Storm Control (Broadcast/Multi-cast/Un-known Unicast) Jumbo Frame Support 9.6KB © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 17 Power Input 100~240VAC Dimension (H*W*D) 44*330*210 mm Power, PoE, Link/Act, SFP Operating Temperature 0~45°C Operating Humidity 5~90% (non-condensing) Weight 2.2 KG Certification VCCI, CE, FCC Class A © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 18 IEEE 802.1s - Multiple Spanning Tree IEEE 802.3ad - Link Aggregation Control Protocol (LACP) IEEE 802.1AB - LLDP (Link Layer Discovery Protocol) IEEE 802.1X - Access Control © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 19: Hardware Description

    No Power will be provided and the user must allocate PoE power ma nually. Rear Panel The rear panel of the Full-Management PoE switch contains a power switch and an IEC 60320 plug for power supply. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 20: Hardware Installation

    Cross-connect the transmit channel at each end to the receive channel at the opposite end. For more information regarding to the product safety and maintenance guide, please refer to Appendix A: Product Safety. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 21: Chapter 2: Preparing For Management

    Chrome) as long as your PC and the switch are connected to the same network. Preparation for Serial Console Preparation for Web Interface Preparation for Telnet/SSH Interface © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 22: Preparation For Serial Console

    The following section will use HyperTerminal as an example. Run HyperTerminal on your PC. Give a name to the new console connection. Choose the COM port that is connected to the switch. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 23 Set the serial port settings as: Baud Rate: 115200, Data Bit: 8, Parity: None, Stop Bit: 1, Row Control: None. The system will prompt you to login the out-of-band management CLI. The default username/password is admin/admin. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 24: Preparation For Web Interface

    Launch the web browser (IE, Firefox, or Chrome) on your PC. Type 192.168.2.1 (or the IP address of the switch) in the web browser’s URL field, and press Enter. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 25 Chapter 2: Preparing for Management Preparation for Web Interface The web browser will prompt you to sign in. The default username/password for the configuration web page is admin/admin. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 26: Preparation For Telnet/Ssh Interface

    Input the IP address of the switch in the “Host Name (or IP address)” field. The default IP address of the switch if 192.168.2.1. Choose “SSH” on the “Connection type” section, then press “Enter”. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 27 CLI. PuTTY will prompt you to login after the telnet/SSH connection is established. The default username/password is admin/admin. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 28: Chapter 3: Web Management

    4 categories, which will be discussed in detail in this chapter: Web Management - Configure Web Management - Monitor Web Management - Diagnostic Web Management - Maintenance © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 29: Web Management - Configure

    PoE: Here you can enable/disable the PoE function on each port or assign the power (in Watt) for each port. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 30 The sampled packets will be sent to the designated sFlow receiver (host) for system administrator for analysis. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 31: Configuration - System

    0 to 255, and the allowed content is the ASCII characters from 32 to 126. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 32: System - Ip

    When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server, and reply as a DNS resolver to the client devices on the network. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 33 (:). For example, fe80::215:c5ff:fe03:4dc7. The symbol :: is a special syntax that can be used as a © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 34 If the IPv6 gateway address is link-local, it must specify the next hop VLAN for the gateway. If the IPv6 gateway address is not link-local, system ignores the next hop VLAN for the © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 35 Add Route: Click to add a new IP route. A maximum of 32 routes is supported. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 36: System - Ntp

    Also, you can just input NTP server’s URL here as well. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 37: System - Time

    Daylight Saving Time duration. Disable: Disable the Daylight Saving Time configuration. This is the default setting. Recurring: The configuration of the daylight saving time duration will be applied every year. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 38 Offset - Enter the number of minutes to add during Daylight Saving Time. (Range: 1 to 1440) Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 39: System - Log

    Warning: Send warnings and errors. Error: Send errors. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 40: Configuration - Green Ethernet

    Buffering traffic will give some latency in the traffic. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 41 Enable or disable the EEE functions by check or un-check the check box. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 42: Configuration - Ports

    100Mbps HDX - Forces the cu port in 100Mbps half duplex mode. 100Mbps FDX - Forces the cu port in 100Mbps full duplex mode. 1Gbps FDX - Forces the cu port in 1Gbps full duplex mode. Flow Control © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 43 Reset: Click to undo any changes made locally and revert to previously saved values. Refresh: Click to refresh the page. Any changes made locally will be undone. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 44: Configuration - Dhcp

    1. Press “Add VLAN Range” to add a new VLAN range. 2. Input the VLAN range that you want to disable. 3. Choose Mode to be Disabled. 4. Press “Save” to apply the change. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 45 Add VLAN Range: Click to add a new VLAN range. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 46: Dhcp - Server - Excluded Ip

    Add IP Range: Click to add a new excluded IP range. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 47: Dhcp - Server - Pool

    Display network number of the DHCP address pool. If "-" is displayed, it means not defined. Subnet Mask Display subnet mask of the DHCP address pool. If "-" is displayed, it means not defined. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 48 Add New Pool: Click to add a new DHCP pool. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 49: Dhcp - Snooping

    Untrusted: Configures the port as untrusted source of the DHCP messages. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 50: Dhcp - Relay

    ID 1, port No 8. And the option 82 remote ID value is equal the switch MAC address. Possible modes are: Enabled: Enable DHCP relay information mode operation. When DHCP relay © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 51 Drop: Drop the package when a DHCP message that already contains relay information is received. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 52: Configuration - Security

    10 for a standard user account and privilege level 5 for a guest account. Buttons Add New User: Click to add a new user. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 53 Cancel: Click to undo any changes made locally and return to the Users. Delete User: Delete the current user. Please note that the default user (admin) cannot be deleted. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 54: Security - Switch - Privilege Level

    Port: Everything except 'VeriPHY'. Diagnostics: 'ping' and 'VeriPHY'. Maintenance: CLI- System Reboot, System Restore Default, System Password, Configuration Save, Configuration Load and Firmware Load. Web- Users, Privilege © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 55 Privilege level to have the access to that group. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 56: Security - Switch - Authentication Method

    This is only possible if the Authentication Method is set to a value other than 'none' or 'local'. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 57 Chapter 3: Web Management Security - Switch - Privilege Level values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 58: Security - Switch - Ssh

    Enabled: Enable SSH mode operation. Disabled: Disable SSH mode operation. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 59: Security - Switch - Https

    Enabled: Enable HTTPS redirect mode operation. Disabled: Disable HTTPS redirect mode operation. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 60: Security - Switch - Access Management

    Add New Entry: Click to add a new access management entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 61 Chapter 3: Web Management Security - Switch - Privilege Level values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 62: Security - Switch - Snmp

    The field is applicable only when SNMP version is SNMPv1 or SNMPv2c. If SNMP version is SNMPv3, the community string will be associated with SNMPv3 communities table. It provides more flexibility to configure security name than a SNMPv1 or © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 63 (A-Za-z), digits (0-9), dot (.), dash (-). Spaces are not allowed, the first character must be an alpha character, and the first and last characters must not be a © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 64 USM for authentication and privacy. A unique engine ID for these traps and informs is needed. When "Trap Probe Security Engine ID" is enabled, the ID will be probed © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 65 A unique security name is needed when traps and informs are enabled. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 66: Security - Switch - Snmp - Trap

    (A-Za-z), digits (0-9), dot (.), dash (-). Spaces are not allowed, the first character must be an alpha character, and the first and last characters must not be a © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 67 Add New Entry: Click to add a new user. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 68: Security - Switch - Snmp - Community

    Add New Entry: Click to add a new community entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 69: Security - Switch - Snmp - User

    Auth, Priv: Authentication and privacy. The value of security level cannot be modified if entry already exists. That means it must first be ensured that the value is set correctly. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 70 Add New Entry: Click to add a new community entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 71: Security - Switch - Snmp - Groups

    Add New Entry: Click to add a new community entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 72: Security - Switch - Snmp - Views

    Add New Entry: Click to add a new community entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 73: Security - Switch - Snmp - Access

    The name of the MIB view defining the MIB objects for which this request may potentially set new values. The allowed string length is 1 to 32, and the allowed content is ASCII characters from 33 to 126. Buttons © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 74: Security - Switch - Rmon

    Add New Entry: Click to add a new community entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 75: Security - Switch - Rmon - History

    Add New Entry: Click to add a new community entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 76: Security - Switch - Rmon - Alarm

    OutDiscards: The number of outbound packets that are discarded event the packets are normal. OutErrors: The The number of outbound packets that could not be transmitted © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 77 Add New Entry: Click to add a new community entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 78: Security - Switch - Rmon - Event

    Add New Entry: Click to add a new community entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 79: Security - Network - Limit Control

    The underlying port security will use the shorter requested aging period of all modules that use the functionality. The Aging Period can be set to a number between 10 and 10,000,000 seconds. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 80 Trap: If Limit + 1 MAC addresses is seen on the port, send an SNMP trap. If Aging is disabled, only one SNMP trap will be sent, but with Aging enabled, new SNMP traps will be sent every time the limit gets exceeded. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 81 Add New Entry: Click to add a new community entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 82: Security - Network - Nas (Network Access Server)

    Indicates if NAS is globally enabled or disabled on the stack. If globally disabled, all ports are allowed forwarding of frames. Re-authentication Enabled If checked, successfully authenticated supplicants/clients are re-authenticated after the interval specified by the Re-authentication Period. Re-authentication for © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 83 Hold Time This setting applies to the following modes, i.e. modes using the Port Security functionality to secure MAC addresses: © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 84 When unchecked, RADIUS-server assigned VLAN is disabled on all ports. Guest VLAN Enabled A Guest VLAN is a special VLAN - typically with limited network access - on which © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 85 The value can only be changed if the Guest VLAN option is globally enabled. Port Configuration The table has one row for each port on the selected switch in the stack and a number of © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 86 X seconds (using the AAA configuration page), and suppose that the first server in the list is currently down (but not considered dead). Now, if the supplicant © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 87 EAPOL Start or EAPOL Response Identity frame sent by the supplicant. An exception to this is when no supplicants are attached. In this case, the switch sends © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 88 QoS Class or it's invalid, or the supplicant is otherwise no longer present on the port, the port's QoS Class is immediately reverted to the original QoS Class (which © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 89 Single 802.1X For trouble-shooting VLAN assignments, use the "Monitor→VLANs→VLAN Membership and VLAN Port" pages. These pages show which modules have (temporarily) overridden the current Port VLAN configuration. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 90 EAPOL frame has previously been received on the port (this history is cleared if the port link goes down or the port's Admin State is © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 91 Reinitialize: Forces a reinitialization of the clients on the port and thereby a re-authentication immediately. The clients will transfer to the unauthorized state © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 92 Add New Entry: Click to add a new community entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 93: Security - Network - Acl

    Specify the mirror operation of this port. The allowed values are: Enabled: Frames received on the port are mirrored. Disabled: Frames received on the port are not mirrored. The default value is "Disabled". © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 94 Reset: Click to undo any changes made locally and revert to previously saved values. Refresh: Click to refresh the page; any changes made locally will be undone. Clear: Click to clear the counters. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 95: Security - Network - Acl - Rate Limiter

    Kbits per second. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 96: Security - Network - Acl - Access Control List

    Action Indicates the forwarding action of the ACE. Permit: Frames matching the ACE may be forwarded and learned. Deny: Frames matching the ACE are dropped. Rate Limiter © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 97 First select the ingress port for the ACE, and then select the frame type. Different parameter options are displayed depending on the frame type © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 98 ARP: Only ARP frames can match this ACE. Notice the ARP frames won't match the ACE with ethernet type. IPv4: Only IPv4 frames can match this ACE. Notice the IPv4 frames won't match © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 99 Enabled: If a frame matches the ACE, the ingress port will be disabled. Disabled: Port shut down is disabled for the ACE. Counter The counter indicates the number of times the ACE was hit by a frame. MAC Parameters © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 100 DMAC value. VLAN Parameters VLAN ID Filter Specify the VLAN ID filter for this ACE. Any: No VLAN ID filter is specified. (VLAN ID filter status is "don't-care".) © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 101 Reply: Frame must have ARP Reply or RARP Reply OP flag. Sender IP Filter Specify the sender IP filter for this ACE. Any: No sender IP filter is specified. (Sender IP filter is "don't-care".) © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 102 (THA) settings. 0: RARP frames where THA is not equal to the target MAC address. 1: RARP frames where THA is equal to the target MAC address. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 103 1: ARP/RARP frames where the PRO is equal to IP (0x800). Any: Any value is allowed ("don't-care"). IP Parameters The IP parameters can be configured when Frame Type "IPv4" is selected. IP Protocol Filter © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 104 No: IPv4 frames where the options flag is set must not be able to match this entry. Yes: IPv4 frames where the options flag is set must be able to match this entry. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 105 DIP address in dotted decimal notation. DIP Mask When "Network" is selected for the destination IP filter, you can enter a specific DIP mask in dotted decimal notation. ICMP Parameters © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 106 The allowed range is 0 to 255. A frame that hits this ACE matches this ICMP code value. TCP/UDP Parameters TCP/UDP Source Filter Specify the TCP/UDP source filter for this ACE. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 107 When "Range" is selected for the TCP/UDP destination filter, you can enter a specific TCP/UDP destination range value. The allowed range is 0 to 65535. A frame that hits this ACE matches this TCP/UDP destination value. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 108 0: TCP frames where the URG field is set must not be able to match this entry. 1: TCP frames where the URG field is set must be able to match this entry. Any: Any value is allowed ("don't-care"). © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 109 0x86DD(IPv6). A frame that hits this ACE matches this EtherType value. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. Cancel: Return to the previous page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 110: Security - Network - Ip Source Guard

    Reset: Click to undo any changes made locally and revert to previously saved values. Translate Dynamic to Static: Click to translate all dynamic entries to static entries. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 111: Security - Network - Ip Source Guard - Static Table

    Add New Entry: Click to add a new entry to the Static IP Source Guard table. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 112: Security - Network - Arp Inspection

    Only the Global Mode and Port Mode on a given port are enabled, and the setting of "Check VLAN" is disabled, the log type of ARP Inspection will refer to the port setting. There are four log types and possible types are: © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 113 Reset: Click to undo any changes made locally and revert to previously saved values. Translate Dynamic to Static: Click to translate all dynamic entries to static entries. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 114: Security - Network - Arp Inspection - Vlan Configuration

    Reset: Click to undo any changes made locally and revert to previously saved values. Add New Entry: Click to add a new VLAN to the ARP Inspection VLAN table. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 115: Security - Network - Arp Inspection - Static Table

    Add New Entry: Click to add a new entry to the Static IP Source Guard table. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 116: Security - Network - Arp Inspection - Dynamic Table

    VLAN-ID in which the ARP traffic is permitted. MAC Address User MAC address of the entry. IP Address User IP address of the entry. Translate to static © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 117 <<: Updates the table starting from the first entry in the Dynamic ARP Inspection Table. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 118: Security - Aaa

    The secret key - up to 63 characters long - shared between the RADIUS server and the switch. NAS-IP-Address (Attribute 4) The IPv4 address to be used as attribute 4 in RADIUS Access-Request packets. If this © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 119 RADIUS server can be configured as needed. Up to 5 servers are supported. The Delete button can be used to undo the addition of the new server. Buttons © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 120 Chapter 3: Web Management Security - AAA - RADIUS Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 121: Security - Aaa - Tacacs

    To delete a TACACS+ server entry, check this box. The entry will be deleted during the next Save. Hostname The IP address or hostname of the TACACS+ server. Port © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 122 The Delete button can be used to undo the addition of the new server. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 123: Configuration - Aggregation

    The TCP/UDP port number can be used to calculate the destination port for the frame. Check to enable the use of the TCP/UDP Port Number, or uncheck to disable. By default, TCP/UDP Port Number is enabled. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 124 Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 125: Aggregation - Lacp

    Lower number means greater priority. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 126 Chapter 3: Web Management Aggregation - LACP Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 127: Configuration - Loop Protection

    (7 days). A value of zero will keep a port disabled (until next device restart). Port Configuration Port The switch port number of the port. Enable Controls whether loop protection is enabled on this switch port. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 128 Controls whether the port is actively generating loop protection PDU's, or whether it is just passively looking for looped PDU's. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 129: Configuration - Spanning Tree

    The maximum age of the information transmitted by the Bridge when it is the Root Bridge. Valid values are in the range 6 to 40 seconds, and MaxAge must be <= (FwdDelay-1)*2. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 130 30 and 86400 seconds (24 hours). Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 131: Spanning Tree - Msti Mapping

    The revision of the MSTI configuration named above. This must be an integer between 0 and 65535. MSTI Mapping MSTI The bridge instance. The CIST is not available for explicit mapping, as it will receive the VLANs not explicitly mapped. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 132 (I.e. not having any VLANs mapped to it.) Example: 2,5,20-40. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 133: Spanning Tree - Msti Priorities

    MSTI instance number, concatenated with the 6-byte MAC address of the switch forms a Bridge Identifier. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 134: Spanning Tree - Cist Ports

    Valid values are in the range 1 to 200000000. Priority Controls the port priority. This can be used to control priority of ports having identical port cost. (See above). © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 135 Edge status does not effect this setting. A port entering error-disabled state due to this setting is subject to the bridge Port Error Recovery setting as well. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 136 LANs than for shared media. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 137: Spanning Tree - Msti Ports

    Valid values are in the range 1 to 200000000. Priority Controls the port priority. This can be used to control priority of ports having identical © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 138 Get: Click to retrieve settings for a specific MSTI. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 139: Configuration - Ipmc Profile

    When the profile is created, click the edit button to enter the rule setting page of the designated profile. Summary about the designated profile will be shown by clicking the © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 140 Add New IPMC Profile: Click to add new IPMC profile. Specify the name and configure the new entry. Click "Save". Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 141: Ipmc Profile - Address Entry

    |<<: Updates the table starting from the first entry in the IPMC Profile Address Configuration. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 142: Configuration - Mvr

    Check to delete the entry. The designated entry will be deleted during the next save. MVR VID Specify the Multicast VLAN ID. Note: MVR source ports are not recommended to be overlapped with management VLAN ports. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 143 Inactive (I): The designated port does not participate MVR operations. Source (S): Configure uplink ports that receive and send multicast data as source ports. Subscribers cannot be directly connected to source ports. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 144 Check to delete the entry. The designated entry will be deleted during the next save. VLAN ID Display the specific Multicast VLAN ID. This field is not editable. VLAN Name © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 145 |<<: Updates the table starting from the first entry in the MVR Channel Configuration for a specific MVR VLAN. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 146: Configuration - Ipmc

    SSM service model for the groups in the address range. Leave Proxy Enabled Enable IGMP Leave Proxy. This feature can be used to avoid forwarding unnecessary leave messages to the router side. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 147 Enable to limit the number of multicast groups to which a switch port can belong. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 148: Ipmc - Igmp Snooping - Vlan Configuration

    Define the IPv4 address as source address used in IP header for IGMP Querier election. When the Querier address is not set, system uses IPv4 management address of the IP interface associated with this VLAN. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 149 The allowed range is 0 to 31744 in tenths of seconds, default query response interval is 100 in tenths of seconds (10 seconds). LLQI (LMQI for IGMP) Last Member Query Interval. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 150 VLAN is also created. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 151: Ipmc - Igmp Snooping - Port Group Filtering

    Navigate: List the rules associated with the designated profile. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 152: Ipmc - Mld Snooping

    Proxy Enabled Enable MLD Proxy. This feature can be used to avoid forwarding unnecessary join and leave messages to the router side. Router Port © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 153 Enable to limit the number of multicast groups to which a switch port can belong. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 154: Ipmc - Mld Snooping - Vlan Configuration

    MLD operating on hosts and routers within a network. The allowed selection is MLD-Auto, Forced MLDv1, Forced MLDv2, default compatibility value is MLD-Auto. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 155 The allowed range is 0 to 31744 in tenths of seconds, default last listener query interval is 10 in tenths of seconds (1 second). Unsolicited Report Interval. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 156 VLAN is also created. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 157: Ipmc - Mld Snooping - Port Group Filtering

    Navigate: List the rules associated with the designated profile. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 158: Configuration - Lldp

    Tx Reinit controls the amount of seconds between the shutdown frame and a new LLDP initialization. Valid values are restricted to 1 - 10 seconds. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 159 LLDP neighbors table. CDP TLV "Port ID" is mapped to the LLDP "Port ID" field. CDP TLV "Version and Platform" is mapped to the LLDP "System Description" field. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 160 Optional TLV: When checked the "management address" is included in LLDP information transmitted. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 161: Lldp - Lldp-Med

    LLDPDU to start within a second, when a new LLDP-MED neighbor has been detected in order share LLDP-MED information as fast as possible to © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 162 0.0 represents the floor level associated with ground level at the main entrance. Map Datum The Map Datum is used for the coordinates given in these options: © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 163 Street - Example: Poppelvej. Leading street direction Leading street direction - Example: N. Trailing street suffix Trailing street suffix - Example: SW. Street suffix Street suffix - Example: Ave, Platz. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 164 Emergency Call Service (e.g. E911 and others), such as defined by TIA or NENA. Emergency Call Service Emergency Call Service ELIN identifier data format is defined to carry the ELIN identifier © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 165 It should be noted that LLDP-MED is not intended to run on links other than between Network Connectivity Devices and Endpoints, and therefore does not need to advertise © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 166 7. Streaming Video - for use by broadcast or multicast based video content distribution and other similar applications supporting streaming video services that require © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 167 Click “Add New Policy” to add a new policy. Specify the Application type, Tag, VLAN ID, L2 Priority and DSCP for the new policy. Click "Save". The number of policies supported is 32 © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 168 Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 169: Configuration - Poe

    In this mode the Maximum Power fields have no effect For all modes: If a port uses more power than the reserved power for the port, the port is shut down. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 170 PoE+: Enables PoE+ IEEE 802.3at (Class 4 PDs limited to 30W) Priority The Priority represents the ports priority. There are three levels of power priority named Low, High and Critical. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 171 It is recommended to set the Power Management Mode to Actual Consumption, and set the ports that connect to crucial devices to High or Critical as shown in the figures down below. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 172: Configuration - Mac Table

    Each port can do learning based upon the following settings: Auto Learning is done automatically as soon as a frame with unknown SMAC is received. Disable No learning is done. Secure © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 173 VLAN ID, MAC address, and port members for the new entry. Click "Save". Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 174: Configuration - Vlans

    The port mode (default is Access) determines the fundamental behavior of the port in question. A port can be in one of three modes as described below. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 175 In addition to the characteristics described for trunk ports, hybrid ports have these abilities: Can be configured to be VLAN tag unaware, C-tag aware, S-tag aware, or S-custom-tag aware Ingress filtering can be controlled © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 176 On ingress, frames with a VLAN tag with a TPID = 0x8100 or equal to the Ethertype configured for Custom-S ports get classified to the VLAN ID embedded in the tag. If a © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 177 This option is only available for ports in Hybrid mode. Allowed VLANs Ports in Trunk and Hybrid mode may control which VLANs they are allowed to become © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 178 By default, the field is left blank, which means that the port may become a member of all possible VLANs. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 179: Configuration - Private Vlan

    Click "OK" to discard the incorrect entry, or click "Cancel" to return to the editing and make a correction. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 180 3 seconds. Refresh: Click to refresh the page immediately. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 181: Private Vlan - Port Isolation

    3 seconds. Refresh: Click to refresh the page immediately. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 182: Configuration - Vcl

    "Save". The “Delete” button can be used to undo the addition of new MAC-based VLANs. The maximum possible MAC-based VLAN entries are limited to 256. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 183 |<<: Updates the table starting from the first entry in the MAC-based VLAN Table. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 184: Vcl - Port-Based Vlan

    (xx) in string is a hexadecimal value ranges from 0x00-0xff. b. PID: If the OUI is hexadecimal 000000, the protocol ID is the Ethernet type © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 185 Reset: Click to undo any changes made locally and revert to previously saved values. Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 186: Vcl - Port-Based Vlan - Group To Vlan

    Group to VLAN mappings are limited to 64. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 187 VCL - Port-based VLAN - Group to VLAN Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 188: Vcl - Ip Subnet-Based Vlan

    Any IP address/mask can be configured for the IP subnet-based VLAN entry. Legal values for a VLAN ID are 1 through 4095. The IP subnet-based VLAN entry is enabled on the selected stack switch unit when you © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 189 Reset: Click to undo any changes made locally and revert to previously saved values. Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Refreshes the displayed table. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 190: Configuration - Voice Vlan

    The actual aging time will be situated between the [age_time; 2 * age_time] interval. Traffic Class Indicates the Voice VLAN traffic class. All traffic on the Voice VLAN will apply this class. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 191 LLDP: Detect telephony device by LLDP. Both: Both OUI and LLDP. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 192: Voice Vlan - Oui

    Add New Entry: Click to add a new access management entry. Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 193: Configuration - Qos

    If the port is VLAN aware, the frame is tagged and Tag Class. is enabled, then the frame is classified to a DPL that is mapped from the PCP and DEI value in the tag. Otherwise the frame is classified to the default DPL. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 194 Source: Enable SMAC/SIP matching. Destination: Enable DMAC/DIP matching. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 195 Reset: Click to undo any changes made locally and revert to previously saved values. Cancel: Click to undo any changes made locally and return to the previous page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 196: Qos - Port Policing

    If flow control is enabled and the port is in flow control mode, then pause frames are sent instead of discarding frames. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 197: Qos - Port Scheduler

    Shows the scheduling mode for this port. Shows the weight for this queue and port. This page allows you to configure the Scheduler and Shapers for a specific port. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 198 Controls the unit of measure for the port shaper rate as "kbps" or "Mbps". The default value is "kbps". Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 199 100-1000000 when the "Unit" is "kbps", and it is restricted to 1-13200 when the "Unit" is "Mbps". Queue Shaper Unit Controls the unit of measure for the queue shaper rate as "kbps" or "Mbps". The default value is "kbps". © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 200 Reset: Click to undo any changes made locally and revert to previously saved values. Cancel: Click to undo any changes made locally and return to the previous page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 201: Qos - Port Shaping

    Shows "disabled" or actual queue shaper rate - e.g. "800 Mbps". Port Shows "disabled" or actual port shaper rate - e.g. "800 Mbps". This page allows you to configure the Scheduler and Shapers for a specific port. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 202 Controls the unit of measure for the port shaper rate as "kbps" or "Mbps". The default value is "kbps". Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 203 100-1000000 when the "Unit" is "kbps", and it is restricted to 1-13200 when the "Unit" is "Mbps". Queue Shaper Unit Controls the unit of measure for the queue shaper rate as "kbps" or "Mbps". The default value is "kbps". © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 204 Reset: Click to undo any changes made locally and revert to previously saved values. Cancel: Click to undo any changes made locally and return to the previous page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 205: Qos - Port Tag Remarking

    Shows the tag remarking mode for this port. Classified: Use classified PCP/DEI values. Default: Use default PCP/DEI values. Mapped: Use mapped versions of QoS class and DP level. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 206 Controls the mapping of the classified (QoS class, DP level) to (PCP, DEI) values when the mode is set to Mapped. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 207 Chapter 3: Web Management QoS - Port Tag Remarking Cancel: Click to undo any changes made locally and return to the previous page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 208: Qos - Port Dscp

    DSCP=0: Classify if incoming (or translated if enabled) DSCP is 0. Selected: Classify only selected DSCP for which classification is enabled as specified in DSCP Translation window for the specific DSCP. All: Classify all DSCP. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 209 Remap: DSCP from analyzer is remapped and frame is remarked with remapped DSCP value. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 210: Qos - Dscp-Based Qos

    QoS class value can be any of (0-7) Drop Precedence Level (0-3) Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 211: Qos - Dscp Translation

    2. Remap DP1 Controls the remapping for frames with DP level 1. 1. Remap DP0 Select the DSCP value from select menu to which you want to remap. DSCP value ranges form 0 to 63. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 212 Select the DSCP value from select menu to which you want to remap. DSCP value ranges form 0 to 63. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 213: Qos - Dscp Classification

    DSCP Select the classified DSCP value (0-63). Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 214: Qos - Qos Control List

    The default value is 'Any'. SMAC Match specific source MAC address or 'Any'. If a port is configured to match on DMAC/DIP, this field indicates the DMAC. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 215 Add: Inserts a new QCE before the current row. Edit: Edits the QCE. Up: Moves the QCE up the list. Down: Moves the QCE down the list. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 216 Chapter 3: Web Management QoS - QoS Control List Delete: Deletes the QCE. Add: The lowest plus sign adds a new entry at the bottom of the QCE listings. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 217: Qos - Storm Control

    Controls the unit of measure for the storm control rate as kbps, Mbps, fps or kfps . The default value is "kbps". Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 218: Configuration - Mirroring

    Rx only: Frames received on this port are mirrored on the mirror port. Frames transmitted are not mirrored. Tx only: Frames transmitted on this port are mirrored on the mirror port. Frames received are not mirrored. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 219 Tx frames. Because of this, mode for the selected mirror port is limited to Disabled or Rx only. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 220: Configuration - Upnp

    100 to 86400. Buttons Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 221: Configuration - Gvrp

    When GVRP is enabled a maximum number of VLANs supported by GVRP is specified. By default this number is 20. This number can only be changed when GVRP is turned off. Buttons Save: Click to save changes. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 222: Gvrp - Port Config

    This page allows you to enable a port for GVRP. Button Save: Click to save changes. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 223: Configuration - Sflow

    Web or CLI interface or through SNMP. This read-only field shows the owner of the current sFlow configuration and assumes values as follows: If sFlow is currently unconfigured/unclaimed, Owner contains <none>. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 224 Enables/disables flow sampling on this port. Flow Sampler Sampling Rate The statistical sampling rate for packet sampling. Set to N to sample on average 1/Nth of the packets transmitted/received on the port. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 225 Save: Click to save changes. Note that sFlow configuration is not persisted to non-volatile memory. Reset: Click to undo any changes made locally and revert to previously saved values. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 226: Web Management - Monitor

    Timing server running on the switch, if any. System Uptime The period of time the device has been operational. Switch ID The switch ID. Chip ID The Chip ID of this switch. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 227 The date when the switch software was produced. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 228: System - Cpu Load

    Microsoft Internet Explorer will need to have a plugin installed to support SVG. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 229: System - Ip Status

    The destination IP network or host address of this route. Gateway The gateway address of this route. Status The status flags of the route. Neighbour cache IP Address The IP address of the entry. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 230 The Link (MAC) address for which a binding to the IP address given exist.. Buttons Refresh: Click to refresh the page immediately. Auto-refresh: Check this box to refresh the page automatically. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 231: System - Log

    <<: Updates the system log entries, ending at the last entry currently displayed. >>: Updates the system log entries, starting from the last entry currently displayed. >>|: Updates the system log entries, ending at the last available entry ID. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 232: System - Detailed Log

    <<: Updates the system log entry to the previous available entry ID. >>: Updates the system log entry to the next available entry ID. >>|: Updates the system log entry to the last available entry ID. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 233: Monitor - Green Ethernet

    Shows if the system is currently saving power due to PerfectReach. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 234: Monitor - Ports

    RJ45 ports SFP ports X2 ports Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 235: Ports - Traffic Overview

    Refresh: Click to refresh the page immediately. Clear: Clears the counters for all ports. Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 236: Ports - Qos Statistics

    Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. Clear: Clears the counters for all ports. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 237: Ports - Qcl Status

    'Yes', otherwise it is always 'No'. Please note that conflict can be resolved by releasing the H/W resources required to add QCL entry on pressing 'Resolve Conflict' button. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 238 Resolve Conflict: Click to release the resources required to add QCL entry, in case the conflict status for any QCL entry is 'yes'. Refresh : Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 239: Ports - Detailed Statistics

    The number of received and transmitted (good and bad) unicast packets. Rx and Tx Multicast The number of received and transmitted (good and bad) multicast packets. Rx and Tx Broadcast © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 240 Note 2: Long frames are frames that are longer than the configured maximum frame length for this port. Transmit Error Counters Tx Drops The number of frames dropped due to output buffer congestion. Tx Late/Exc. Coll. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 241 Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Note: The port select box determines which port is affected by clicking the buttons. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 242: Monitor - Dhcp

    Number of bindings that administrator assigns an IP address to a client. That is, the pool is of host type. Expired Binding Number of bindings that their lease time expired or they are cleared from Automatic/Manual type bindings. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 243 Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. Clear: Click to Clears DHCP Message Received Counters and DHCP Message Sent Counters. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 244: Dhcp - Server - Binding

    Expired bindings. Clear Manual: Click to clear all Manual bindings and Change them to Expired bindings. Clear Expired: Click to clear all Expired bindings and free them. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 245: Dhcp - Server - Declined Ip

    List of IP addresses declined. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 246: Dhcp - Snooping Table

    Switch Port Number for which the entries are displayed. IP Address User IP address of the entry. IP Subnet Mask User IP subnet mask of the entry. DHCP Server Address © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 247 |<<: Updates the table starting from the first entry in the Dynamic DHCP snooping Table. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 248: Dhcp - Relay Statistics

    The number of relayed packets from server to client. Transmit Error The number of packets that resulted in error while being sent to servers. Receive from Client The number of received packets from server. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 249 Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. Clear: Clear all statistics. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 250: Dhcp - Detailed Statistics

    The number of inform (option 53 with value 8) packets received and transmitted. Rx and Tx Lease Query The number of lease query (option 53 with value 10) packets received and transmitted. Rx and Tx Lease Unassigned © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 251 Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. Clear: Clears the counters for the selected port. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 252: Monitor - Security

    Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. Clear: Clear all statistics. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 253: Security - Network

    A one-letter abbreviation of the user module. This is used in the Users column in the port status table. Port Status The table has one row for each port on the selected switch in the stack and a number of columns. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 254 (-). Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 255: Security - Network - Port Security - Port

    (-) will be shown. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 256: Security - Network - Nas - Switch

    MAC-based authentication. QoS Class QoS Class assigned to the port by the RADIUS server if enabled. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 257 Guest VLANs here. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 258: Security - Network - Nas - Port

    If the port is moved to the Guest VLAN, "(Guest)" is appended to the VLAN ID. Read more about Guest VLANs here. Port Counters EAPOL Counters These supplicant frame counters are available for the following administrative states: Force Authorized Force Unauthorized © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 259 Single 802.1X Multi 802.1X Backend Server Counters These backend (RADIUS) frame counters are available for the following administrative states: Port-based 802.1X Single 802.1X Multi 802.1X MAC-based Auth. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 260 Information about the last supplicant/client that attempted to authenticate. This information is available for the following administrative states: Port-based 802.1X Single 802.1X Multi 802.1X MAC-based Auth. Selected Counters © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 261 Hold Time seconds. Last Authentication Shows the date and time of the last authentication of the client (successful as well as © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 262 Clear This: Click to clear both the port counters and all of the attached client's counters. The "Last Client" will not be cleared, however. This button is available in the following modes: Multi 802.1X MAC-based Auth.X © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 263: Security - Network - Acl Status

    Indicates the rate limiter number of the ACE. The allowed range is 1 to 16. When Disabled is displayed, the rate limiter operation is disabled. Forward packet that matched the specific ACE to CPU. Counter © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 264 The select box determines which ACL user is affected by clicking the buttons. Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 265: Security - Network - Arp Inspection

    User MAC address of the entry. IP Address User IP address of the entry. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 266: Security - Network - Ip Source Guard

    Use the << button to start over. Port Switch Port Number for which the entries are displayed. VLAN ID VLAN-ID in which the IP traffic is permitted. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 267 << : Updates the table starting from the first entry in the Dynamic IP Source Guard Table. >> : Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 268 Switch Port Number for which the entries are displayed. VLAN ID VLAN-ID in which the IP traffic is permitted. IP Address User IP address of the entry. MAC Address Source MAC address. Buttons © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 269 |<<: Updates the table starting from the first entry in the Dynamic IP Source Guard Table. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 270: Security - Aaa

    The number of seconds left before this occurs is displayed in parentheses. This state is only reachable when more than one server is enabled. RADIUS Accounting Servers © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 271 Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 272: Security - Aaa - Radius Details

    Use the server select box to switch between the backend servers to show details for. Packet Counters RADIUS authentication server packet counter. There are seven receive and four transmit counters. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 273 Chapter 3: Web Management Security - AAA - RADIUS Details Other Info This section contains information about the state of the server and the latest round-trip time. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 274 Use the server select box to switch between the backend servers to show details for. Packet Counters RADIUS accounting server packet counter. There are five receive and four transmit counters. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 275 3 seconds. Refresh: Click to refresh the page immediately. Clear: Clears the counters for the selected server. The "Pending Requests" counter will not be cleared by this operation. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 276: Security - Switch - Rmon

    The total number of packets (including bad packets, broadcast packets, and multicast packets) received. Broad-cast The total number of good packets received that were directed to the broadcast address. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 277 The total number of packets (including bad packets) received that were between 256 to 511 octets in length. 512~1023 The total number of packets (including bad packets) received that were between 512 to 1023 octets in length. 1024~1588 © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 278 |<<: Updates the table starting from the first entry in the Statistics table, i.e. the entry with the lowest ID. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 279: Security - Switch - Rmon - History

    The total number of octets of data (including those in bad packets) received on the network. Pkts The total number of packets (including bad packets, broadcast packets, and multicast packets) received. Broadcast © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 280 |<<: Updates the table starting from the first entry in the History table, i.e., the entry with the lowest History Index and Sample Index >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 281: Security - Switch - Rmon - Alarm

    The value of the statistic during the last sampling period. Startup Alarm The alarm that may be sent when this entry is first set to valid. Rising Threshold Rising threshold value. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 282 |<<: Updates the table starting from the first entry in the Alarm Table, i.e. the entry with the lowest ID. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 283: Security - Switch - Rmon - Events

    |<<: Updates the table starting from the first entry in the Event Table, i.e. the entry with the lowest Event Index and Log Index. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 284: Monitor - Lacp

    Shows which ports are a part of this aggregation for this switch/stack. The format is: "Switch ID:Port". Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 285: Lacp - Port Status

    Partner Port The partner's port number connected to this port. Partner Prio The partner's port priority. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 286 Chapter 3: Web Management LACP - Port Status refresh occurs every 3 seconds. Refresh: Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 287: Lacp - Port Statistics

    Shows how many unknown or illegal LACP frames have been discarded at each port. Buttons Auto-refresh: Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. Clear: Clears the counters for all ports. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 288: Monitor - Loop Protection

    The time of the last loop event detected. Buttons Refresh: Click to refresh the page immediately. Auto-refresh: Check this box to enable an automatic refresh of the page at regular intervals. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 289: Monitor - Spanning Tree

    The time since last Topology Change occurred. Buttons Refresh: Click to refresh the page immediately. Auto-refresh: Check this box to enable an automatic refresh of the page at regular intervals. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 290: Spanning Tree - Port Status

    The time since the bridge port was last initialized. Buttons Refresh: Click to refresh the page immediately. Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 291: Spanning Tree - Port Statistics

    Refresh: Click to refresh the page immediately. Clear: Click to reset the counters. Auto-refresh: Check this box to enable an automatic refresh of the page at regular intervals. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 292: Monitor - Mvr

    Auto-refresh: Check this box to enable an automatic refresh of the page at regular intervals. Refresh: Click to refresh the page immediately. Clear: Clears all Statistics counters. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 293: Mvr - Mvr Channel Groups

    Auto-refresh: Automatic refresh occurs every 3 seconds. Refresh: Refreshes the displayed table starting from the input fields. |<<: Updates the table starting from the first entry in the MVR Channels (Groups) © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 294 Chapter 3: Web Management MVR - MVR Channel Groups Information Table. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 295: Mvr - Mvr Sfm Information

    Group address of the group displayed. Port Switch port number. Mode Indicates the filtering mode maintained per (VLAN ID, port number, Group Address) basis. It can be either Include or Exclude. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 296 |<<: Updates the table starting from the first entry in the MVR SFM Information Table. >>: Updates the table, starting with the entry after the last entry currently displayed © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 297: Monitor - Ipmc

    V2 Reports Received The number of Received V2 Reports. V3 Reports Received The number of Received V3 Reports. V2 Leaves Received The number of Received V2 Leaves. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 298 Indicate whether specific port is a router port or not. Buttons Auto-refresh: Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. Clear: Clears all Statistics counters. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 299: Ipmc - Igmp Snooping - Groups Information

    |<<: Updates the table, starting with the first entry in the IGMP Group Table. >>: Updates the table, starting with the entry after the last entry currently © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 300 Chapter 3: Web Management IPMC - IGMP Snooping - Groups Information displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 301: Ipmc - Igmp Snooping - Ipv4 Sfm Information

    VLAN ID of the group. Group Group address of the group displayed. Port Switch port number. Mode Indicates the filtering mode maintained per (VLAN ID, port number, Group Address) © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 302 |<<: Updates the table starting from the first entry in the IGMP SFM Information Table >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 303: Ipmc - Mld Snooping

    V1 Leaves Received The number of Received V1 Leaves. Router Port Display which ports act as router ports. A router port is a port on the Ethernet switch © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 304 Indicate whether specific port is a router port or not. Buttons Auto-refresh: Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. Clear: Clears all Statistics counters. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 305: Ipmc - Mld Snooping - Groups Information

    |<<: Updates the table, starting with the first entry in the MLD Group Table. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 306: Ipmc - Mld Snooping - Ipv6 Sfm Information

    Use the “|<<” button to start over. MLD SFM Information Table Columns VLAN ID VLAN ID of the group. Group Group address of the group displayed. Port Switch port number. Mode © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 307 |<<: Updates the table starting from the first entry in the MLD SFM Information Table. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 308: Monitor - Lldp

    8. Station only 9. Reserved When a capability is enabled, the capability is followed by (+). If the capability is disabled, the capability is followed by (-). © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 309 This could for instance hold the neighbour's IP address. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 310: Lldp - Lldp-Med Neighbours

    Each LLDP-MED Endpoint Device Class is defined to build upon the capabilities defined for the previous Endpoint Device Class. For-example will any LLDP-MED Endpoint Device claiming compliance as a Media Endpoint (Class II) also support all aspects of TIA-1057 © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 311 PC-based softphones, or other communication appliances that directly support the end user. Discovery services defined in this class include provision of location identifier (including ECS / E911 information), embedded L2 switch support, inventory management. LLDP-MED Capabilities © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 312 TCP with buffering would not be an intended use of this application type. 8. Video Signaling - for use in network topologies that require a separate policy for the video Signaling than for the video media. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 313 If Auto-negotiation is supported and Auto-negotiation status is disabled, the 802.3 PMD operating mode will be determined the operational MAU type field value rather than by auto-negotiation. Auto-negotiation Capabilities © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 314 Auto-negotiation Capabilities shows the link partners MAC/PHY capabilities. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 315: Lldp - Poe

    PD device from a PSE device, or the minimum power a PSE device is capable of sourcing over a maximum length cable based on its current © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 316 W, it is represented as "reserved" Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 317: Lldp - Eee

    For example, if the © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 318 Green - Switch and link partner have agreed on wakeup times. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 319: Lldp - Port Statistics

    The port on which LLDP frames are received or transmitted. Tx Frames The number of LLDP frames transmitted on the port. Rx Frames The number of LLDP frames received on the port. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 320 Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page. Clear: Clears the local counters. All counters (including global counters) are cleared upon reboot. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 321: Monitor - Poe

    The Power Requested shows the requested amount of power the PD wants to be reserved. Power Allocated The Power Allocated shows the amount of power the switch has allocated for the PD. Power Used © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 322 Invalid PD - PD detected, but is not working correctly. Buttons Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 323: Monitor - Mac Table

    Type Indicates whether the entry is a static or a dynamic entry. MAC address The MAC address of the entry. VLAN The VLAN ID of the entry. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 324 |<<: Updates the table starting from the first entry in the MAC Table, i.e. the entry with the lowest VLAN ID and MAC address. >>: Updates the table, starting with the entry after the last entry currently displayed. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 325: Monitor - Vlans

    VLAN ID found in the VLAN Table. The "VLAN" input field allows the user to select the starting point in the VLAN Table. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 326 : Select VLAN Users from this drop down list. Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh: Click to refresh the page immediately. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 327: Vlans - Vlan Ports

    The field is empty if not overridden by the selected user. Frame Type Shows the acceptable frame types (All, Taged, Untagged) that a given user wants to © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 328 : Select VLAN Users from this drop down list. Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds. Refresh : Click to refresh the page immediately. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 329: Monitor - Vcl

    Buttons Refresh: Refreshes the displayed table. Auto-refresh: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds (only present if stacking is enabled). © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 330: Monitor - Sflow

    The number of UDP datagrams that has failed transmission. The most common source of errors is invalid sFlow receiver IP/hostname configuration. To diagnose, paste the receiver's IP address/hostname into the Ping Web page © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 331 3 seconds (only present if stacking is enabled). Refresh: Click to refresh the page. Clear Receiver: Clears the sFlow receiver counters. Clear Port: Clears the per-port counters. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 332: Web Management - Diagnostics

    The payload size of the ICMP packet. Values range from 2 bytes to 1452 bytes. Ping Count The count of the ICMP packet. Values range from 1 time to 60 times. Ping Interval © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 333 The interval of the ICMP packet. Values range from 0 second to 30 seconds. Buttons Start: Click to start transmitting ICMP packets. New Ping: Click to re-start diagnostics with PING. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 334: Diagnostics - Ping6

    The count of the ICMP packet. Values range from 1 time to 60 times. Ping Interval The interval of the ICMP packet. Values range from 0 second to 30 seconds. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 335 Do not specify egress interface for loopback address. Do specify egress interface for link-local or multicast address. Buttons Start: Click to start transmitting ICMP packets. New Ping: Click to re-start diagnostics with PING. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 336: Diagnostics - Veriphy

    Short C - Cross-pair short to pair C Short D - Cross-pair short to pair D Cross A - Abnormal cross-pair coupling with pair A Cross B - Abnormal cross-pair coupling with pair B © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 337 Cross C - Abnormal cross-pair coupling with pair C Cross D - Abnormal cross-pair coupling with pair D Length: The length (in meters) of the cable pair. The resolution is 3 meters © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 338: Web Management - Maintenance

    You can restart the stack on this page. After restart, the stack will boot normally. Buttons Yes: Click to restart device. No: Click to return to the Port State page without restarting. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 339: Maintenance - Factory Defaults

    'loopback' packets will be transmitted at port 1. If a 'loopback' packet is received at port 2 the switch will do a restore to default © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 340: Maintenance - Software

    Warning: The management web page will stop functioning during the firmware updating process. Do not restart or power off the device at this time or the switch may malfunction. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 341: Software - Image Select

    Activate Alternate Image: Click to use the alternate image. This button may be disabled depending on system state. Cancel: Cancel activating the backup image. Navigates away from this page. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 342: Maintenance - Configuration

    Note: After making any settings to the switch, you must save the current running-config to the startup-config. All your settings will be lost if you didn’t save the current running-config to the startup-config and reboot the switch. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 343: Configuration - Download

    Here you can choose the configuration file you would like to save to your PC, including: Running-config Startup-config Default-config Buttons Download Configuration: Click this button to save the configuration you chose. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 344: Configuration - Upload

    Buttons Upload Configuration: Click this button to upload the configuration you chose. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 345: Configuration - Activate

    Buttons Activate Configuration: Click this button to activate the configuration you chose. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 346: Configuration - Delete

    Here you can delete the configuration files saved on the switch. File Name Choose the configuration file that you would like to delete here. Buttons Delete Configuration File: Click this button to delete the configuration you chose. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 347 Before powering up this product, please make sure that the electric power source meets this product’s requirement. DO NOT use other power adapters if this product comes with its own power adapter in the package. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 348 ALLNET GmbH Computersysteme declares that the device ALL-SG8910PM is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC or 2014/30/EU. The Declaration of conformity can be found under this link: www.allnet.de/downloads.html ALLNET GmbH Computersysteme Maistrasse 2 82110 Germering Tel.: +49 (0)89 894 222 - 22...
  • Page 349 OTHER PROGRAMS), EVEN IF SUCH HOLDER OR OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Written Offer for Source Code For binaries that you receive from ALLNET GmbH Computersysteme on physical media or within the download of the offered © ALLNET GmbH Computersysteme 2017 - All rights reserved...
  • Page 350 82110 Germering Your request should include: (i) the name of the covered binary, (ii) the version number of the ALLNET product containing the covered binary, (iii) your name, (iv) your company name (if applicable) and (v) your return mailing and email address (if available). We may charge you a nominal fee to cover the cost of the media and distribution.
  • Page 351 Program is not restricted, and the output from the Program is covered only if its contents constitute a work based on the Program (independent of having been made by running the Program). Whether that is true depends on what the Program does. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 352 Accompany it with the complete corresponding machine-readable source code, which must be distributed under the terms of Sections and 2 above on a medium customarily used for software interchange; or, © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 353 License and any other pertinent obligations, then as a consequence you may not distribute the Program at all. For example, if a patent license would not permit royalty-free redistribution of the Program © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 354 12. IN NO EVENT UNLESS REQUIRED BY APPLICABLE LAW OR AGREED TO IN WRITING WILL ANY COPYRIGHT HOLDER, OR ANY OTHER PARTY WHO MAY MODIFY AND/OR REDISTRIBUTE THE PROGRAM AS PERMITTED ABOVE, BE LIABLE TO YOU FOR © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 355 You should also get your employer (if you work as a programmer) or your school, if any, to sign a "copyright disclaimer" for the program, if necessary. Here is a sample; alter the names: Yoyodyne, Inc., hereby disclaims all copyright interest in the program © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 356 And you must show them these terms so they know their rights. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 357 GNU LESSER GENERAL PUBLIC LICENSE TERMS AND CONDITIONS FOR COPYING, DISTRIBUTION AND MODIFICATION © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 358 (For example, a function in a library to compute square roots has a purpose that is entirely well-defined independent of the application. Therefore, Subsection 2d requires that any application-supplied function or table used by this © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 359 (because it contains portions of the Library), rather than a "work that uses the library". The executable is therefore covered by this License. Section 6 states terms for distribution of such executables. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 360 For an executable, the required form of the "work that uses the Library" must include any data and utility programs needed for reproducing the executable from it. However, as a special exception, the materials to be distributed need not © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 361 If any portion of this section is held invalid or unenforceable under any particular circumstance, the balance of the section is intended to apply, and the section as a whole is intended to apply in other circumstances. © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 362 DAMAGES, INCLUDING ANY GENERAL, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE LIBRARY (INCLUDING BUT NOT LIMITED TO LOSS OF DATA OR DATA BEING RENDERED INACCURATE © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...
  • Page 363 Yoyodyne, Inc., hereby disclaims all copyright interest in the library `Frob' (a library for tweaking knobs) written by James Random Hacker. <signature of Ty Coon>, 1 April 1990 Ty Coon, President of Vice That's all there is to it! © ALLNET GmbH Computersysteme 2017 - All rights reserved Errors and omissions excepted...

Table of Contents