Shock And Vibration Specifications; Table 8 Non-Operating Shock Specifications (Unpackaged) - Quantum Tape Drive A-Series User Manual

A-series tape drives
Hide thumbs Also See for Tape Drive A-Series:
Table of Contents

Advertisement

Shock and Vibration
Specifications
Table 8 Non-operating Shock
Specifications (Unpackaged)
Quantum A-Series Tape Drives User's Guide
Item
Rewind Tape Speed
Linear Search Tape Speed
Average Rewind Time**
Maximum Rewind Time**
Average Access Time** (from
BOT)
Maximum Access Time** (from
BOT)
Load to BOT**
Unload from BOT**
Nominal Tape Tension
*
Depending on data type and Ethernet network connection
configuration. GigE is required for 36 MB/s.
** Note that data is typical; times may be longer if error recovery
time is necessary, or if the command times out for any reason.
The following tables provide non-operating and operating shock and
1
vibration specifications for the SDLT 600 tape drive.
Shock (Unpackaged)
Pulse Shape
Peak Acceleration
Duration
Specification
160 ips
160 ips
77 seconds
156 seconds
79 seconds
190 seconds
18 seconds (typical)
63 seconds (unformatted tape)
19 seconds
Stationary: 3.0 ± 0.5 oz
Operating Speed: 3.5 ± 0.5 oz
Square wave
40 G
10 ms (180 inches/
second)
Functional Specifications
½ sine pulse
140 G
2 ms
35